Aluminium Conductor XLPE Insulated Overhead ABC Cable
Prodotto in dettaglio
Informazioni di Base
Informazioni Aggiuntive.
Descrizione del prodotto
Aluminium Conductor XLPE Insulated Overhead ABC Cable
Applications:
Used to supply 3 phase power, usually from a pole- mounted transformer, to the user’s service head where connect to the service entrance cable. To be used at voltages of 600 volts or less phase to phase and at conductor temperatures not to exceed 75° C for PE insulated Conductors or 90° C for crosslinked polyethylene (XLPE) insulated conductors.
Construction:
Conductors are concentrically stranded, compressed 1350-H19 aluminum. Insulated with either polyethylene or XLP crosslinked polyethylene. Neutral messengers are concentrically stranded 6201, AAC, or ACSR. One conductor is manufactured with an extruded ridge for phase identification.
Installation:
For service at 600 volts or less (phase to phase) at a maximum conductor temperature of 75 0C for Polyethylene insulation or 90 0C for Cross-Linked (XLPE) insulation
Specifications
Quadruplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474.
B-230 Aluminum Wire, 1350-H19 for electrical purposes
B-231 Aluminum Conductors, concentric-lay-stranded
B-232 Aluminum Conductors, concentric-lay-stranded, coated steel reinforced(ACSR)
B-399 Concentric-Lay-Stranded, 6201-T81 Aluminum Alloy Conductors.
B-498 Zinc-coated Steel Core Wire for Aluminum Conductors, steel reinforced(ACSR/AZ)
Triplex Service Drop cable meets or exceeds all aplicable requierements of
ANSI/ICEA S-76-474.
Remarks:
1) Designated sizes are: ACSR 6/1 diameter equivalent and AAC with equivalent
Resistivity per ASTMB-399 for 6201.
2) Conductor temperature of 90° C for XLPE 75° C for PE; Ambient temperatures of
40° C; Emissivity 0.9; 2ft. /sec/wind in sun.
The advantages of our company:
1) Our company is a professional supplier of various kinds of cables for over 10 years.
2) The quality of our products are guaranteed.
3) The price is averagely 10%~20% lower than the other competitors
4) Huge Inventory Allows Us To Ship Your Order Immediately
5) Our employees are all capable and professinal. They can offer you the Prompt Courteous Service.
6) We ship worldwide.
Specification:
(1)Self-supporting
Phase |
Phase |
Phase |
Approx.Overall Diameter |
Max. D.C. Resistance of Conductor at 20ºC |
|||
AAC+UV-XLPE |
Compact Conductor |
UV-XLPE Insulation |
|||||
No.X Normal Cross Section of Cores |
No.of Al Wires |
Overall Diameter |
Normal Thickness |
Min. |
Diameter |
||
No. X mm2 |
– |
mm |
mm |
mm |
mm |
mm |
ohm/km |
1 X 10 |
7 |
4.05 |
1.0 |
0.8 |
6.05 |
6.05 |
3.08 |
1 X 16 |
7 |
4.8 |
1.2 |
0.98 |
7.2 |
7.20 |
1.91 |
1 X 25 |
7 |
6 |
1.2 |
0.98 |
8.4 |
8.40 |
1.20 |
1 X 35 |
7 |
7.0 |
1.4 |
1.16 |
9.8 |
9.80 |
0.868 |
1 X 50 |
7 |
8.3 |
1.4 |
1.16 |
11.1 |
11.10 |
0.641 |
1 X 70 |
19 |
9.8 |
1.4 |
1.16 |
12.6 |
12.60 |
0.443 |
1 X 95 |
19 |
11.6 |
1.6 |
1.34 |
14.8 |
14.80 |
0.320 |
1 X 120 |
19 |
13 |
1.6 |
1.34 |
16.2 |
16.20 |
0.253 |
1 X 150 |
19 |
14.6 |
1.8 |
1.52 |
18.2 |
18.20 |
0.206 |
1 X 185 |
36 |
16.2 |
2.0 |
1.70 |
20.2 |
20.20 |
0.164 |
1 X 240 |
36 |
18.4 |
2.2 |
1.88 |
22.8 |
22.80 |
0.125 |
2 X 10 |
7 |
4.05 |
1.0 |
0.8 |
6.05 |
12.10 |
3.08 |
2 X 16 |
7 |
4.8 |
1.2 |
0.98 |
7.2 |
14.40 |
1.91 |
2 X 25 |
7 |
6 |
1.2 |
0.98 |
8.4 |
16.80 |
1.20 |
2 X 35 |
7 |
7.0 |
1.4 |
1.16 |
9.8 |
19.60 |
0.868 |
2 X 50 |
7 |
8.3 |
1.4 |
1.16 |
11.1 |
22.20 |
0.641 |
2 X 70 |
19 |
9.8 |
1.4 |
1.16 |
12.6 |
25.20 |
0.443 |
2 X 95 |
19 |
11.6 |
1.6 |
1.34 |
14.8 |
29.60 |
0.320 |
2 X 120 |
19 |
13 |
1.6 |
1.34 |
16.2 |
32.40 |
0.253 |
2 X 150 |
19 |
14.6 |
1.8 |
1.52 |
18.2 |
36.40 |
0.206 |
2 X 185 |
36 |
16.2 |
2.0 |
1.70 |
20.2 |
40.40 |
0.164 |
2 X 240 |
36 |
18.4 |
2.2 |
1.88 |
22.8 |
45.60 |
0.125 |
3 X 10 |
7 |
4.05 |
1.0 |
0.8 |
6.05 |
13.07 |
3.08 |
3 X 16 |
7 |
4.8 |
1.2 |
0.98 |
7.2 |
15.55 |
1.91 |
3 X 25 |
7 |
6 |
1.2 |
0.98 |
8.4 |
18.14 |
1.20 |
3 X 35 |
7 |
7.0 |
1.4 |
1.16 |
9.8 |
21.17 |
0.868 |
3 X 50 |
7 |
8.3 |
1.4 |
1.16 |
11.1 |
23.98 |
0.641 |
3 X 70 |
19 |
9.8 |
1.4 |
1.16 |
12.6 |
27.22 |
0.443 |
3 X 95 |
19 |
11.6 |
1.6 |
1.34 |
14.8 |
31.97 |
0.320 |
3 X 120 |
19 |
13 |
1.6 |
1.34 |
16.2 |
34.99 |
0.253 |
3 X 150 |
19 |
14.6 |
1.8 |
1.52 |
18.2 |
39.31 |
0.206 |
3 X 185 |
36 |
16.2 |
2.0 |
1.70 |
20.2 |
43.63 |
0.164 |
3 X 240 |
36 |
18.4 |
2.2 |
1.88 |
22.8 |
49.25 |
0.125 |
4 X 10 |
7 |
4.05 |
1.0 |
0.8 |
6.05 |
14.64 |
3.08 |
4 X 16 |
7 |
4.8 |
1.2 |
0.98 |
7.2 |
17.42 |
1.91 |
4 X 25 |
7 |
6 |
1.2 |
0.98 |
8.4 |
20.33 |
1.20 |
4 X 35 |
7 |
7.0 |
1.4 |
1.16 |
9.8 |
23.72 |
0.868 |
4 X 50 |
7 |
8.3 |
1.4 |
1.16 |
11.1 |
26.86 |
0.641 |
4 X 70 |
19 |
9.8 |
1.4 |
1.16 |
12.6 |
30.49 |
0.443 |
4 X 95 |
19 |
11.6 |
1.6 |
1.34 |
14.8 |
35.82 |
0.320 |
4 X 120 |
19 |
13 |
1.6 |
1.34 |
16.2 |
39.20 |
0.253 |
4 X 150 |
19 |
14.6 |
1.8 |
1.52 |
18.2 |
44.04 |
0.206 |
4 X 185 |
36 |
16.2 |
2.0 |
1.70 |
20.2 |
48.88 |
0.164 |
4 X 240 |
36 |
18.4 |
2.2 |
1.88 |
22.8 |
55.18 |
0.125 |
(2) Phase + Neutral
Phase |
Neutral |
Phase |
Neutral |
Approx.Overall Diameter |
Max. D.C. Resistance of Conductor at 20ºC |
||||
AAC+UV-XLPE |
AAAC |
Compact Conductor |
UV-XLPE Insulation |
Conductor |
|||||
Phase |
Neutral |
||||||||
No.X Normal Cross Section of Cores |
No.X Normal Cross Section of Cores |
No.of Al.Wire |
Overall Dia. |
Normal Thickness |
Min. |
No./Dia. of Al Alloy Wire |
|||
No. X mm2 |
No. X mm2 |
– |
mm |
mm |
Min. |
No./mm |
mm |
ohm/km |
ohm/km |
1 X 16 |
1 X 16 |
7 |
4.8 |
1.2 |
0.98 |
7/1.70 |
12.30 |
1.91 |
2.217 |
1 X 25 |
1 X 25 |
7 |
6 |
1.2 |
0.98 |
7/2.10 |
14.70 |
1.20 |
1.393 |
1 X 35 |
1 X 35 |
7 |
7.0 |
1.4 |
1.16 |
7/2.50 |
17.30 |
0.868 |
1.007 |
1 X 50 |
1 X 50 |
7 |
8.3 |
1.4 |
1.16 |
7/3.00 |
20.10 |
0.641 |
0.744 |
1 X 70 |
1 X 70 |
19 |
9.8 |
1.4 |
1.16 |
7/3.50 |
23.10 |
0.443 |
0.514 |
1 X 95 |
1 X 95 |
19 |
11.6 |
1.6 |
1.34 |
19/2.50 |
27.30 |
0.320 |
0.371 |
1 X 120 |
1 X 120 |
19 |
13 |
1.6 |
1.34 |
19/2.80 |
30.20 |
0.253 |
0.294 |
1 X 150 |
1 X 150 |
19 |
14.6 |
1.8 |
1.52 |
37/2.25 |
33.95 |
0.206 |
0.239 |
1 X 185 |
1 X 185 |
36 |
16.2 |
2.0 |
1.70 |
37/2.50 |
37.70 |
0.164 |
0.190 |
1 X 240 |
1 X 240 |
36 |
18.4 |
2.2 |
1.88 |
61/2.25 |
43.05 |
0.125 |
0.145 |
2 X 16 |
1 X 16 |
7 |
4.8 |
1.2 |
0.98 |
7/1.70 |
14.04 |
1.91 |
2.217 |
2 X 25 |
1 X 25 |
7 |
6 |
1.2 |
0.98 |
7/2.10 |
16.63 |
1.20 |
1.393 |
2 X 35 |
1 X 35 |
7 |
7.0 |
1.4 |
1.16 |
7/2.50 |
19.51 |
0.868 |
1.007 |
2 X 50 |
1 X 50 |
7 |
8.3 |
1.4 |
1.16 |
7/3.00 |
22.46 |
0.641 |
0.744 |
2 X 70 |
1 X 70 |
19 |
9.8 |
1.4 |
1.16 |
7/3.50 |
25.70 |
0.443 |
0.514 |
2 X 95 |
1 X 95 |
19 |
11.6 |
1.6 |
1.34 |
19/2.50 |
30.31 |
0.320 |
0.371 |
2 X 120 |
1 X 120 |
19 |
13 |
1.6 |
1.34 |
19/2.80 |
33.41 |
0.253 |
0.294 |
2 X 150 |
1 X 150 |
19 |
14.6 |
1.8 |
1.52 |
37/2.25 |
37.55 |
0.206 |
0.239 |
2 X 185 |
1 X 185 |
36 |
16.2 |
2.0 |
1.70 |
37/2.50 |
41.69 |
0.164 |
0.190 |
2 X 240 |
1 X 240 |
36 |
18.4 |
2.2 |
1.88 |
61/2.25 |
47.41 |
0.125 |
0.145 |
3 X 16 |
1 X 16 |
7 |
4.8 |
1.2 |
0.98 |
7/1.70 |
16.15 |
1.91 |
2.217 |
3 X 25 |
1 X 25 |
7 |
6 |
1.2 |
0.98 |
7/2.10 |
19.06 |
1.20 |
1.393 |
3 X 35 |
1 X 35 |
7 |
7.0 |
1.4 |
1.16 |
7/2.50 |
22.32 |
0.868 |
1.007 |
3 X 50 |
1 X 50 |
7 |
8.3 |
1.4 |
1.16 |
7/3.00 |
25.59 |
0.641 |
0.744 |
3 X 70 |
1 X 70 |
19 |
9.8 |
1.4 |
1.16 |
7/3.50 |
29.22 |
0.443 |
0.514 |
3 X 95 |
1 X 95 |
19 |
11.6 |
1.6 |
1.34 |
19/2.50 |
34.42 |
0.320 |
0.371 |
3 X 120 |
1 X 120 |
19 |
13 |
1.6 |
1.34 |
19/2.80 |
37.87 |
0.253 |
0.294 |
3 X 150 |
1 X 150 |
19 |
14.6 |
1.8 |
1.52 |
37/2.25 |
42.56 |
0.206 |
0.239 |
3 X 185 |
1 X 185 |
36 |
16.2 |
2.0 |
1.70 |
37/2.50 |
47.25 |
0.164 |
0.190 |
3 X 240 |
1 X 240 |
36 |
18.4 |
2.2 |
1.88 |
61/2.25 |
53.63 |
0.125 |
0.145 |
(3) Phase + Neutral + Service Connection
Phase |
Neutral |
Service Connection |
Phase |
Neutral |
Service Connection |
Approx.Overall Diameter of Bundled Cable |
|||||
AAC+UV-XLPE |
AAAC+UV-XLPE |
AAC+UV-XLPE |
Conductor |
UV-XLPE |
Conductor |
UV-XLPE |
Compact Conductor |
UV-XLPE |
|||
No.X Normal Cross Section of Cores |
No.X Normal Cross Section of Cores |
No.X Normal Cross Section of Cores |
No. of Al. Wire |
Overall Dia. |
Normal |
No./Dia. of Al. Wire |
Normal |
No. of Al. Wire |
Overall Dia. |
Normal |
|
No. X mm2 |
No. X mm2 |
No. X mm2 |
– |
mm |
mm |
mm |
mm |
No./mm |
mm |
mm |
mm |
3 X 16 |
1 X 50 |
1 X 16 |
7 |
4.8 |
1.2 |
7/3.0 |
1.4 |
7 |
4.8 |
1.2 |
26.2 |
3 X 25 |
1 X 50 |
1 X 16 |
7 |
6 |
1.2 |
7/3.0 |
1.4 |
7 |
4.8 |
1.2 |
28.6 |
3 X 35 |
1 X 50 |
1 X 16 |
7 |
7.0 |
1.4 |
7/3.0 |
1.4 |
7 |
4.8 |
1.2 |
31.4 |
3 X 50 |
1 X 50 |
1 X 16 |
7 |
8.3 |
1.4 |
7/3.0 |
1.4 |
7 |
4.8 |
1.2 |
34 |
3 X 70 |
1 X 50 |
1 X 16 |
19 |
9.8 |
1.4 |
7/3.0 |
1.4 |
7 |
4.8 |
1.2 |
37 |
3 X 95 |
1 X 50 |
1 X 16 |
19 |
11.6 |
1.6 |
7/3.0 |
1.4 |
7 |
4.8 |
1.2 |
41.4 |
3 X 120 |
1 X 50 |
1 X 16 |
19 |
13 |
1.6 |
7/3.0 |
1.4 |
7 |
4.8 |
1.2 |
44.2 |
3 X 16 |
1 X 50 |
2 X 16 |
7 |
4.8 |
1.2 |
7/3.0 |
1.4 |
7 |
4.8 |
1.2 |
26.2 |
3 X 25 |
1 X 50 |
2 X 16 |
7 |
6 |
1.2 |
7/3.0 |
1.4 |
7 |
4.8 |
1.2 |
28.6 |
3 X 35 |
1 X 50 |
2 X 16 |
7 |
7.0 |
1.4 |
7/3.0 |
1.4 |
7 |
4.8 |
1.2 |
31.4 |
3 X 50 |
1 X 50 |
2 X 16 |
7 |
8.3 |
1.4 |
7/3.0 |
1.4 |
7 |
4.8 |
1.2 |
34 |
3 X 70 |
1 X 50 |
2 X 16 |
19 |
9.8 |
1.4 |
7/3.0 |
1.4 |
7 |
4.8 |
1.2 |
37 |
3 X 95 |
1 X 50 |
2 X 16 |
19 |
11.6 |
1.6 |
7/3.0 |
1.4 |
7 |
4.8 |
1.2 |
41.4 |
3 X 120 |
1 X 50 |
2 X 16 |
19 |
13 |
1.6 |
7/3.0 |
1.4 |
7 |
4.8 |
1.2 |
44.2 |
- Next: Single-Core Electrical Wire/PVC Wire/Building Wire
- Previous: Electric Welding Cable/Power Cable/Copper Wire
Contact us
Simile o correlato
- No related articles