Anti-Corrosion Type ACSR Conductor with IEC Certificate

 Anti-Corrosion Type ACSR Conductor with IEC Certificate

Prodotto in dettaglio

Informazioni di Base

Model No.:CK1V_TD3KW2AAR}A~D3T(FV
Applicazione: Alto
Voltaggio: Cavo a bassa tensione e media
Corrente: Cavo DC
Materiale di isolamento: Nudo
Forma Materiale: Filo tondo
Certificazione: ISO , CCC , CE , RoHS , UL

Informazioni Aggiuntive.

Marchio:RNEDA
Imballaggio:Wooden Drum
Standard:IEC DIN ASTM VDE BS
Origine:China
Codice SA:7614100000
Capacità di Produzione:1000km Per Month

Descrizione del prodotto

ACSR conductor
ASTM B232 standard Merlin acsr conductor
ACSR,AAC,AAAC,ASCSR&ACAR conductor widely used in power transmission lines with various voltage levels. since they have such good characteristics as simple structure, convenient installation and maintenance, low cost for the line, large transmission capacity and are also suitable for laying across rivers and valleys where special geographical teatures exist.

1. Specification:

(1) all aluminium conductor (AAC)
(2) all aluminimum alloy conductor(AAAC)
(3) aluminum conductor steel reinforced (ACSR)
(4) anti-corrosion type ACSR
(5) aluminimum conductor aluminimum clad steel reinforced(ACSR/AW)
(6)rear earth aluminimum conductor steel reinforced(ACSR/RE)
(7)aluminimum conductor aluminimum alloy reinforced(ACAR)

ACSR British Sizes BS215-1
Code name Nominal Al. Area Stranding and Wire diameter Sectional area of Al. Total sectional area Overall diameter Calculated Breaking Load Calculate D.C Resistance at 20 Final modulus of elasticity
mm2 Al. Steel mm2 mm2 mm daN /km hbar
Mole 10 6/1.50 1/1.50 10.52 4.50 43 414 2.706 7900
Squirrel 20 6/2.11 1/2.11 20.94 6.33 85 788 1.368 7900
Gopher 25 6/2.36 1/2.36 26.24 7.08 106 961 1.093 7900
Weasel 30 6/2.59 1/2.59 31.61 7.77 128 1146 0.9077 7900
Fox 35 6/2.79 1/2.79 36.66 8.37 149 1320 0.7822 7900
Ferret 40 6/3.00 1/3.00 42.41 9.00 172 1520 0.6766 7900
Rabbit 50 6/3.35 1/3.35 52.88 10.05 214 1835 0.5426 7900
Mink 60 6/3.66 1/3.66 63.18 10.98 255 2180 0.4545 7900
Shunk 60 12/2.59 7/2.59 63.27 12.95 465 5300 0.4567 10500
Beaver 70 6/3.99 1/3.99 74.82 11.97 302 2570 0.3825 7900
Horse 70 12/2.79 7/2.79 73.37 13.95 538 6120 0.3936 10500
Racoon 75 6/4.10 1/4.10 79.20 12.30 320 2720 0.3622 7900

2. Elative manufacturing standards: IEC83, IEC1089, 31, B232, BS215, DIN48204

(1). Standard: IEC61089, BS215 part2, ASTM B232, DIN48204, BS EN50182
(2). Specification: ACSR is composed by bare concentric-lay-stranded galvanized steel wire(s) with aluminum wires surrounded by one or more layers of helically. Greased ACSR can also be supplied.
(3). Application: ACSR is widely used in overhead electric power transmission and distribution lines with various voltage levels

We can supply this conductor according to different recognized standards, such as IEC61089, BS215, BS EN 50182: 2001, STM B231, CSA C49, DIN480201, JIS C3109, customer special specification also can be satisfied.

ACSR conductor

Standard: ASTM B232 ,IEC61089, BS215 part2, DIN48204, BS EN50182, GB/T 1179-2008

Brief Description:
ACSR conductor consists of a solid or stranded steel core surrounded by strands of aluminium (E.C. GRADE).
ACSR Conductor may be manufactured for having a wide range of tensile strength as per requirement.
The principal advantage of these conductors are high tensile strength and light weight with longer spans as well as
with lesser supports. Due to the greater diameter of ACS Conductor a much higher corona limit can be obtained causing
big advantages on high as well as extra high voltage overhead lines.

Applications:
Used as bare overhead transmission cable and as primary and secondary distribution cable.
ACSR Conductor offers optimal strength for line design. Variable steel core stranding enables
desired strength to be achieved without sacrificing ampacity. ACSR Conductor are used extensively
for overhead ground wires, river crossings etc. These ACSR Conductor are available with us in various types for
meeting the exact requirements of the clients.

Package:In coils, wooden drums, steel drums or steel-wooden drums.
We could producing according to the customers’ requirements.Welcome your request for any quotations.

Aluminum Conductors Steel Reinforced ASTM B 232
Code name Area Stranding and wire diameter Approx. overall diameter Weight Nominal breaking load Nominal DC resistance at 20 deg.
Nominal Alum. Steel Total Alum. Steel Alum. Steel Total
AWG or MCM mm2 mm2 mm2 mm mm mm kg/km kg/km kg/km kN Ohm/km
TURKEY 6 13.29 2.19 15.48 6/1.68 1/1.68 5.04 37 17 54 5.24 2.1586
SWAN 4 21.16 3.55 24.71 6/2.12 1/2.12 6.36 58 27 85 8.32 1.3557
SWANATE 4 21.16 5.35 26.51 7/1.96 1/2.61 6.53 58 42 100 10.53 1.3557
SPARROW 2 33.61 5.61 39.22 6/2.67 1/2.67 8.01 92 44 136 12.7 0.8535
SPARATE 2 33.61 8.52 42.13 7/2.47 1/3.30 8.24 92 67 159 16.11 0.8535
RAVEN 1/0 53.48 8.9 62.38 6/3.37 1/3.37 10.11 147 69 216 19.32 0.5364
QUAIL 2/0 67.42 11.23 78.65 6/3.78 1/3.78 11.34 185 88 273 23.62 0.4255
PIGEON 3/0 85.03 14.19 99.22 6/4.25 1/4.25 12.75 233 110 343 29.41 0.3373
PENGUIN 4/0 107.23 17.87 125.1 6/4.77 1/4.77 14.31 294 139 433 37.06 0.2675
PARTRIDGE 266.8 135.16 22 157.16 26/2.57 7/2.00 16.28 374 172 546 50.29 0.2143
MERLIN 336.4 170.45 9.48 179.93 18/3.47 1/3.47 17.35 470 74 544 38.23 0.1691
LINNET 336.4 170.45 27.81 198.26 26/2.89 7/2.25 18.31 472 217 689 62.71 0.1699
ORIOLE 336.4 170.45 39.81 210.26 30/2.69 7/2.69 18.83 473 311 784 77.27 0.1704
IBIS 397.5 201.42 32.77 234.19 26/3.14 7/2.44 19.88 558 256 814 72.11 0.1438
LARK 397.5 201.42 46.97 248.39 30/2.92 7/2.92 20.44 560 367 927 88.69 0.1442
PELICAN 477 241.68 13.42 255.10 18/4.14 1/4.14 20.70 666 105 771 52.16 0.1193
FLICKER 477 241.68 31.29 272.97 24/3.58 7/2.39 21.49 670 245 915 76.66 0.1199
HAWK 477 241.68 39.42 281.10 26/3.44 7/2.67 21.79 670 308 978 86.65 0.1199
HEN 477 241.68 56.39 298.07 30/3.20 7/3.20 22.40 671 441 1112 105.34 0.1201
OSPREY 556.5 282.00 15.68 297.68 18/4.47 1/4.47 22.35 777 122 899 60.88 0.1022
PARAKEET 556.5 282.00 36.58 318.58 24/3.87 7/2.58 23.22 781 286 1067 88.22 0.1027
DOVE 556.5 282.00 45.94 327.94 26/3.72 7/2.89 23.55 781 359 1140 101.03 0.1027
EAGLE 556.5 282.00 65.81 347.81 30/3.46 7/3.46 24.21 783 515 1298 122.92 0.103
PEACOCK 605 306.58 39.74 346.32 24/4.03 7/2.69 24.20 849 311 1160 95.88 0.0945
SQUAB 605 306.58 49.94 356.52 26/3.87 7/3.01 24.51 850 390 1240 108.14 0.0945
TEAL 605 306.58 69.87 376.45 30/3.61 19/2.16 25.24 851 548 1399 133.59 0.0947
GROSBEAK 636 322.26 52.45 374.71 26/3.97 7/3.09 25.15 893 409 1302 111.8 0.08989
STARLING 715.5 362.58 59.03 421.61 26/4.21 7/3.28 26.68 1005 461 1466 125.91 0.07989
TERN 795 402.84 27.87 430.71 45/3.38 7/2.25 27.03 1116 217 1333 97.37 0.07191
CONDOR 795 402.84 52.19 455.03 54/3.08 7/3.08 27.72 1116 408 1524 124.45 0.07191
CUCKOO 795 402.84 52.19 455.03 24/4.62 7/3.08 27.74 1116 408 1524 123.94 0.07191
DRAKE 795 402.84 65.61 468.35 26/4.44 7/3.45 28.11 1116 512 1628 139.92 0.07191
MALLARD 795 402.84 91.87 494.71 30/4.14 19/2.48 28.96 1119 719 1838 171.18 0.07208
RAIL 954 483.42 33.42 516.84 45/3.70 7/2.47 29.61 1339 262 1601 115.63 0.05992
CURLEW 1033.5 523.68 67.87 591.55 54/3.52 7/3.52 31.68 1451 530 1981 161.8 0.05531
BLUEJAY 1113 563.93 39.03 602.96 45/4.00 7/2.66 31.98 1563 305 1868 132.63 0.05136
FINCH 1113 563.93 71.55 635.48 54/3.65 19/2.19 32.85 1570 560 2150 174.41 0.05161
GRACKLE 1192.5 604.26 76.58 680.84 54/3.77 19/2.27 33.97 1682 600 2282 186.38 0.04817
BITTERN 1272 644.51 44.52 689.03 45/4.27 7/2.85 34.17 1785 349 2134 151.48 0.04494
DIPPER 1351.5 684.84 47.10 731.94 45/4.40 7/2.92 35.16 1898 368 2266 160.7 0.0423
MARTIN 1351.5 684.84 86.71 771.55 54/4.02 19/2.41 36.17 1906 679 2585 206.05 0.0425
LAPWING 1590 805.68 55.48 861.16 45/4.77 7/3.18 38.16 2232 435 2667 187.02 0.03595
FALCON 1590 805.68 102.13 907.81 54/4.36 19/2.62 39.26 2243 799 3042 242.55 0.03613
DOTTEREL 176.9 89.48 52.19 141.67 12/3.08 7/3.08 15.42 248 409 657 78.5 0.3237
DORKING 190.8 96.71 56.39 153.10 12/3.20 7/3.20 16.03 268 441 709 84.8 0.2995
COCHIN 211.8 107.10 62.45 169.55 12/3.37 7/3.37 16.84 297 488 785 93.9 0.2705
Aluminum Conductors Steel Reinforced BS 215 Part 2
Code name Area Stranding and wire diameter Approx. overall diameter Weight Nominal breaking load Nominal DC resistance at 20 deg.
Nominal Alum. Steel Total Alum. Steel Alum. Steel Total
mm2 mm2 mm2 mm2 mm mm mm kg/km kg/km kg/km kN Ohm/km
MOLE 10 10.62 1.77 12.39 6/1.50 1/1.50 4.50 29 14 43 4.14 2.076
SQUIRREL 20 20.94 3.49 24.43 6/2.11 1/2.11 6.33 58 27 85 7.88 1.368
GOPHER 25 26.25 4.37 30.62 6/2.36 1/2.36 7.08 72 34 106 9.61 1.093
WEASEL 30 31.61 5.27 36.88 6/2.59 1/2.59 7.77 87 41 128 11.45 0.9077
FOX 35 36.66 6.11 42.77 6/2.79 1/2.79 8.37 101 48 149 13.2 0.7822
FERRET 40 42.41 7.07 49.48 6/3.00 1/3.00 9 117 55 172 15.2 0.6766
RABBIT 50 52.88 8.82 61.7 6/3.35 1/3.35 10.05 145 69 214 18.35 0.5426
HORSE 70 73.37 42.8 116.17 12/2.79 7/2.79 13.95 203 335 538 61.2 0.3936
RACOON 75 79.2 13.2 92.4 6/4.10 1/4.10 12.3 217 103 320 27.2 0.3622
OTTER 80 83.88 13.98 97.86 6/4.22 1/4.22 12.66 230 109 339 28.80 0.3419
CAT 90 95.40 15.90 111.30 6/4.50 1/4.50 13.50 262 124 386 32.70 0.3007
HARE 100 105.00 17.50 122.50 6/4.72 1/4.72 14.16 288 137 425 36.00 0.2733
DOG 100 105 13.5 118.5 6/4.72 7/1.57 14.15 288 106 394 32.7 0.2733
TIGER 125 131.1 30.6 161.7 30/2.36 7/2.36 16.52 362 240 602 58 0.2202
WOLF 150 158 36.9 194.9 30/2.59 7/2.59 18.13 437 289 726 69.2 0.1828
LYNX 175 183.4 42.8 226.2 30/2.79 7/2.79 19.53 507 335 842 79.8 0.1576
CARACAL 175 184.2 10.3 194.5 18/3.61 1/3.61 18.05 507 80 587 41.1 0.1563
PANTHER 200 212 49.5 261.5 30/3.00 7/3.00 21 586 388 974 92.25 0.1363
BEAR 250 264 61.6 325.6 30/3.35 7/3.35 23.45 730 483 1213 111.1 0.1093
BISON 350 381.8 49.5 431.3 54/3.00 7/3.00 27 1056 388 1444 120.9 0.07573
DEER 400 429.3 100.2 529.5 30/4.27 7/4.27 29.89 1186 785 1971 178.5 0.06726
ZEBRA 400 428.9 55.6 484.5 54/3.18 7/3.18 28.62 1186 435 1621 131.9 0.0674
MOOSE 500 528.7 68.5 597.2 54/3.53 7/3.53 31.77 1462 537 1999 161.1 0.0547

ACSR Aluminum Conductor Steel-reinforced Power Cable
Features:
1) It is manufactured according to IEC 60889/BS 215/ASTM B 232
2) rated voltage is 500KV or lower
3) This series includes:
a) All aluminum conductors (AAC)
b) All aluminum alloy conductors (AAAC)
c) Aluminum conductor steel reinforced (ACSR)
d) Anti-corrosion ACSR
e) All steel conductors
4)Packing:Standard export wooden drums
(Aluminum Stranded Conductor ,Aluminum Conductor Steel-Reinforced,ACSR,bare wire,AAAC,Aluminum Stranded Conductor, bare wire,bare Aluminum wire, aluminum conductor )

Aluminium Conductor Steel Reinforced Henan ACSR factory

APPLICATIONS

ACSR conductor Used as bare overhead transmission conductor and as primary and secondary distribution conductor and messenger support.
ACSR offers optimal strength for line design. Variable steel core stranding enables desired strength to be achieved without sacrificing ampacity.

SPECIFICATIONS

ACSR bare conductor meets or exceeds the following ASTM specifications:
? B230 Aluminum 1350-H19 Wire for Electrical Purposes.
? B232 Concentric-Lay-Stranded Aluminum Conductors, Coated-Steel Reinforced (ACSR).
? B498 Zinc-Coated (Galvanized) Steel Core Wire for Use in Overhead Electrical Conductors.
? B500 Metallic Coated Stranded Steel Core for Use in Overhead Electrical Conductors.

CONSTRUCTION

? Aluminum 1350-H19 wires, concentrically stranded about a steel core. Standard core wire for ACSR is class A galvanized.
? Class A core stranding is also available in zinc-5% aluminum-mischmetal alloy coating.
? For aluminum-clad (AW) ACSR, please refer to the ACSR/AW catalog sheet
? Additional corrosion protection is available through the application of grease to the core or infusion of the complete cable with grease.
? ACSR conductor is also available in non-specular.

Tags: , ,

Contact us

 

 

 

Success! Thanks for Your Request.
Error! Please Try Again.