Copper Core Steel Wire Armoured Cable

 Copper Core Steel Wire Armoured Cable

Prodotto in dettaglio

Informazioni di Base

Model No.:SWA
Applicazione: Sotterraneo , Centrale elettrica
Voltaggio: Cavo a bassa tensione e media
Corrente: Cavo DC
Materiale di isolamento: XLPE
Certificazione: ISO , CE

Informazioni Aggiuntive.

Marchio:Jiapu
Imballaggio:Wooden Drum or Wooden&Steel Drum
Standard:IEC, BS, DIN, ASTM
Origine:Henan, China
Codice SA:8544492100
Capacità di Produzione:5000km/Month

Descrizione del prodotto

Copper Core Steel Wire Armoured Cable

Application:
Media Voltage XLPE Insulated power cable is used to transmit and distribute power in power transmission and distribution system of 35kV or lower. It is generally applied to the fields including power, construction, mines, metallurgy, petrochemical industry and communication in complete replace of oil immersed paper insulated power cable.

Prpperty:

1.The highest allowed operating temperature of conductor for long-term working is 90 degrees.
2.In short circuit (Max long term is no more than 5 seconds). The highest temperature for conductor is no more than 250 degrees.
3.The cable is laid without horizontal drop limit. The environment temperature should be no lower than 0 when lay. Otherwise it should be preheated.
4.Excellent electrical performance, resistance to chemical corrosion.
5.They can stand advisable traction when laid.They can stand traction from Outside.Left low smoke halogen-free after burned.Retard the burning of the cable.

Specification:

IEC60502,designing and manufacturing special power cable according to the other standards required by the customers.

1)3.6/6(7.2)kV,3.6/6.6(7.2)kV,Three Cores,Al or Cu/XLPE/CTS/STA/PVC Armoured Power Cable

No.X Nominal Cross Section of Conductor Nominal Diameter of Conductor Nominal Thickness of Insulation Nominal Thickness of Copper Tape Screen Nominal Thickness of Inner Sheath Nominal Thickness of Steel Tape Armouring Nominal Thickness of PVC Sheath Approx. Overall Diameter Approx. Weight
Al Conductor Cu Conductor
No. X mm2 mm mm mm mm mm mm mm kg/m kg/m
3 X 25 6.0 2.5 0.1 1.2 0.2 1.9 37.9 1.87 2.32
3 X 35 6.9 2.5 0.1 1.3 0.5 2.0 41.5 2.10 2.73
3 X50 8.2 2.5 0.1 1.3 0.5 2.0 44.3 2.37 3.22
3 X 70 9.7 2.5 0.1 1.4 0.5 2.1 47.9 2.77 4.00
3 X 95 11.3 2.5 0.1 1.4 0.5 2.2 51.6 3.21 4.91
3 X 120 12.8 2.5 0.1 1.5 0.5 2.4 55.4 3.69 5.84
3 X 150 14.2 2.5 0.1 1.5 0.5 2.5 58.6 4.15 6.85
3 X 185 15.9 2.5 0.1 1.5 0.5 2.6 62.5 4.73 8.11
3 X 240 18.3 2.6 0.1 1.6 0.5 2.7 68.5 5.62 10.05
3 X 300 20.4 2.8 0.1 1.7 0.5 2.9 74.5 6.55 12.11
3 X 400 23.2 3.0 0.1 1.9 0.8 3.2 83.6 8.78 15.86
3 X 500 26.4 3.2 0.1 2.1 0.8 3.4 93.0 10.52 18.85

2)6/10(12)kV,6.35/11(12)kV,,Three Cores,Al or Cu/XLPE/CTS/STA/PVC Armoured Power Cable

No.X Nominal Cross Section of Conductor Nominal Diameter of Conductor Nominal Thickness of Insulation Nominal Thickness of Copper Tape Screen Nominal Thickness of Inner Sheath Nominal Thickness of Steel Tape Armouring Nominal Thickness of PVC Sheath Approx. Overall Diameter Approx. Weight
Al Conductor Cu Conductor
No. X mm2 mm mm mm mm mm mm mm kg/m kg/m
3 X 25 6.0 3.4 0.1 1.3 0.5 2.0 43.4 2.16 2.61
3 X 35 6.9 3.4 0.1 1.3 0.5 2.0 45.4 2.36 2.99
3 X50 8.2 3.4 0.1 1.4 0.5 2.2 48.8 2.69 3.54
3 X 70 9.7 3.4 0.1 1.5 0.5 2.3 52.4 3.10 4.33
3 X 95 11.3 3.4 0.1 1.5 0.5 2.4 56.1 3.56 5.26
3 X 120 12.8 3.4 0.1 1.5 0.5 2.5 59.5 4.04 6.19
3 X 150 14.2 3.4 0.1 1.5 0.5 2.6 62.7 4.49 7.19
3 X 185 15.9 3.4 0.1 1.6 0.5 2.6 66.6 5.12 8.49
3 X 240 18.3 3.4 0.1 1.7 0.5 2.8 72.4 5.99 10.42
3 X 300 20.4 3.4 0.1 1.8 0.5 3.0 77.5 6.86 12.42
3 X 400 23.2 3.4 0.1 1.9 0.8 3.2 85.4 8.97 16.05
3 X 500 26.4 3.4 0.1 2.0 0.8 3.4 93.7 10.65 19.50

3)8.7/10(15)kV,Three Cores,Al or Cu/XLPE/CTS/STA/PVC Armoured Power Cable

No.X Nominal Cross Section of Conductor Nominal Diameter of Conductor Nominal Thickness of Insulation Nominal Thickness of Copper Tape Screen Nominal Thickness of Inner Sheath Nominal Thickness of Steel Tape Armouring Nominal Thickness of PVC Sheath Approx. Overall Diameter Approx. Weight
Al Conductor Cu Conductor
No. X mm2 mm mm mm mm mm mm mm kg/m kg/m
3 X 25 6.0 4.5 0.1 1.4 0.5 2.1 48.6 2.53 2.98
3 X 35 6.9 4.5 0.1 1.4 0.5 2.2 50.7 2.76 3.39
3 X50 8.2 4.5 0.1 1.5 0.5 2.3 53.9 3.10 3.95
3 X 70 9.7 4.5 0.1 1.5 0.5 2.4 57.4 3.51 4.74
3 X 95 11.3 4.5 0.1 1.5 0.5 2.6 61.2 4.05 5.75
3 X 120 12.8 4.5 0.1 1.6 0.5 2.6 64.7 4.56 6.72
3 X 150 14.2 4.5 0.1 1.6 0.5 2.7 67.9 5.04 7.74
3 X 185 15.9 4.5 0.1 1.7 0.5 2.8 71.9 5.66 9.04
3 X 240 18.3 4.5 0.1 1.8 0.5 3.0 77.7 6.56 11.00
3 X 300 20.4 4.5 0.1 1.9 0.8 3.2 84.1 8.39 13.96
3 X 400 23.2 4.5 0.1 2.0 0.8 3.3 90.5 9.71 16.79
3 X 500 26.4 4.5 0.1 2.1 0.8 3.5 98.8 11.45 20.57

4)12/20(24)kV, 12.7/22(24)kV,Three Cores,Al or Cu/XLPE/CTS/STA/PVC Armoured Power Cable

No.X Nominal Cross Section of Conductor Nominal Diameter of Conductor Nominal Thickness of Insulation Nominal Thickness of Copper Tape Screen Nominal Thickness of Inner Sheath Nominal Thickness of Steel Tape Armouring Nominal Thickness of PVC Sheath Approx. Overall Diameter Approx. Weight
Al Conductor Cu Conductor
No. X mm2 mm mm mm mm mm mm mm kg/m kg/m
3 X 25
3 X 35 6.9 5.5 0.1 1.5 0.5 2.4 55.6 3.14 3.77
3 X50 8.2 5.5 0.1 1.5 0.5 2.5 58.6 3.49 4.34
3 X 70 9.7 5.5 0.1 1.5 0.5 2.6 62.1 3.93 5.16
3 X 95 11.3 5.5 0.1 1.6 0.5 2.6 65.7 4.46 6.16
3 X 120 12.8 5.5 0.1 1.7 0.5 2.7 69.4 5.00 7.15
3 X 150 14.2 5.5 0.1 1.7 0.5 2.8 72.6 5.49 8.19
3 X 185 15.9 5.5 0.1 1.8 0.5 3.0 76.9 6.16 9.53
3 X 240 18.3 5.5 0.1 1.9 0.8 3.2 83.9 7.87 12.31
3 X 300 20.4 5.5 0.1 2.0 0.8 3.2 88.6 8.96 14.52
3 X 400 23.2 5.5 0.1 2.1 0.8 3.5 95.4 10.35 17.43
3 X 500 26.4 5.5 0.1 2.2 0.8 3.7 103.7 12.45 20.23

5)18/30(36)kV,19/33(36)kV,Three Cores,Al or Cu/XLPE/CTS/STA/PVC Armoured Power Cable

No.X Nominal Cross Section of Conductor Nominal Diameter of Conductor Nominal Thickness of Insulation Nominal Thickness of Copper Tape Screen Nominal Thickness of Inner Sheath Nominal Thickness of Steel Tape Armouring Nominal Thickness of PVC Sheath Approx. Overall Diameter Approx. Weight
Al Conductor Cu Conductor
No. X mm2 mm mm mm mm mm mm mm kg/m kg/m
3 X 25
3 X 35
3 X50 8.2 8.0 0.1 1.7 0.5 2.8 70.4 4.56 5.41
3 X 70 9.7 8.0 0.1 1.7 0.5 2.9 73.9 5.04 6.26
3 X 95 11.3 8.0 0.1 1.8 0.5 3.0 77.7 5.62 7.32
3 X 120 12.8 8.0 0.1 1.9 0.8 3.2 82.8 6.99 9.15
3 X 150 14.2 8.0 0.1 1.9 0.8 3.2 85.8 7.56 10.26
3 X 185 15.9 8.0 0.1 2.0 0.8 3.3 89.9 8.30 11.67
3 X 240 18.3 8.0 0.1 2.1 0.8 3.5 95.7 9.36 13.79
3 X 300 20.4 8.0 0.1 2.2 0.8 3.6 100.6 10.51 16.07
3 X 400 23.2 8.0 0.1 2.3 0.8 3.8 107.2 11.99 19.07
3 X 500 26.4 8.0 0.1 2.4 0.8 4.0 120.1 14.15 23.85