High Quality ACSR (BS 232 standard) for Overhead Application

 High Quality ACSR (BS 232 standard) for Overhead Application

Prodotto in dettaglio

Informazioni di Base

Model No.:BS 232 standard
Tipo: Nudo
Tipo di conduttore: Stranded
Applicazione: Alto
Materiale del conduttore: Alluminio
Forma Materiale: Filo tondo
Certificazione: ISO9001 , CE

Informazioni Aggiuntive.

Marchio:Jiapu
Imballaggio:Wooden Drum or Wooden&Steel Drum
Standard:IEC ASTM BS DIN, Any standard
Origine:Henan, China
Codice SA:7614100000
Capacità di Produzione:3100kilometer/Month

Descrizione del prodotto

AAC, AAAC, ACSR, AACSR&ACAR conductor widely used in power transmission lines with various voltage levels.

Since they have such good characteristics as simple structure, convenient installation and maintenance, low cost for the line, large transmission capacity and are also suitable for laying across rivers and valleys where special geographical teatures exist.

1. Specification:
(1) all aluminium conductor (AAC)
(2) all aluminimum alloy conductor(AAAC)(3) aluminum conductor steel reinforced (ACSR)(4) anti-corrosion type ACSR(5) aluminimum conductor aluminimum clad steel reinforced(ACSR/AW)
(6)rear earth aluminimum conductor steel reinforced(ACSR/RE)
(7)aluminimum conductor aluminimum alloy reinforced(ACAR)

2. Relative manufacturing standards: IEC83, IEC1089, 31, B232, BS215, DIN48204.
1). Standard: IEC61089, BS215 part2, ASTM B232, DIN48204, BS EN50182.
2). Specification: ACSR is composed by bare concentric-lay-stranded galvanized steel wire(s) with aluminum wires surrounded by one or more layers of helically. Greased ACSR can also be supplied.
3). Application: ACSR is widely used in overhead electric power transmission and distribution lines with various voltage levels.

All Aluminum Conductor(AAC)& Aluminum Conductor Steel Reinforced(ACSR))for ASTM
(AAC, ACCR, AAAC, ACSR) Generally Confirming to IS 398 (Part-I, II, IV), IEC-228
(AAAC) Conductor as per ASTM-B-399-1992
(AAAC) Conductor as per BS-3242-1970
(AAAC) Conductor IS: 398-IV-1994
(ACSR) as per ASTM-B-233-1992
(AAC) as per BS-215-1-1970
(AAC) as per IS-398-1: 1976
(AAC) as per ASTM-B-231-1990
(ACSR) as per IS: 398-II: 1976 & IS: 398-V: 1992
(ACSR) BS-215-II-1970
(AACSR) as per IEC-1089-1191

AAC(All aluminum conductor) are suited for overhead power line.
We can supply this conductor according to different recognized standards, such as IEC61089, BS215, BS EN 50182: 2001, ASTM B231, CSA C49, DIN480201, JIS C3109, customer special specification also can be satisfied.
ACSR or ACSR cable or ACSR conductor used for Overhead electrical distribution and transmission lines for distributing power.

Applications:
Used as bare overhead transmission cable and as primary and secondary distribution cable. ACSR offers optimal strength for line design. Variable steel core stranding enables desired strength to be achieved without sacrificing ampacity.
Construction:
Aluminum alloy 1350-H-19 wires, concentrically stranded about a steel core. Core wire for ACSR is available with class A, B, or C galvanizing; ""aluminized"" aluminum coated (AZ); Or aluminum-clad (AW). Additional corrosion protection is available through the application of grease to the corrosion or infusion of the complete cable with grease.

Specifications:
ACSR bare conductor meets or exceeds the following ASTM specifications:
B-230 Aluminum Wire, 1350-H19 for Electrical Purposes
B-231 Aluminum Conductors, Concentric-Lay-Stranded
B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR)
B-341 Aluminum-clad Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AW)
B-498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AZ)
B-500 Zinc Coated and Aluminum Coated Stranded Steel Core for Aluminum Conductors, Steel Reinforced (ACSR)

Notes:
Resistance is calculated using ASTM standard increments of stranding and metal conductivity of 61.2% IACS for EC (1350) and 8% IACS for steel. AC (60Hz) resistance includes current dependent hysteresis loss factor for 1 and 3 layer constructions.
Current ratings are based on 75oC conductor temperature, 25oC ambient, 2ft/s wind, 96/watts/sq. Ft sun, 0.5 coefficients of emissivity and absorption.

Packing:
Standard export wooden drums

Standards IEC61089, BS215 part2, ASTM B232, DIN48204, BS EN50182, JIS C3110
Certificate ISO 9001 and ISO 14001. CE ,SONCAP
Type AAC, AAAC, ACSR, AACSR&ACAR conductor
AAC AAC(All aluminum conductor) are suited for overhead power line.
We can supply this conductor according to different recognized standards, such as IEC61089, BS215, BS EN 50182: 2001, ASTM B231, CSA C49, DIN480201, JIS C3109, customer special specification also can be satisfied.
AAAC (AAAC) Conductor as per ASTM-B-399-1992
ACSR ACSR bare conductor meets or exceeds the following ASTM specifications:
B-230 Aluminum Wire, 1350-H19 for Electrical Purposes
B-231 Aluminum Conductors, Concentric-Lay-Stranded
B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR)
B-341 Aluminum-clad Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AW)
B-498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AZ)
B-500 Zinc Coated and Aluminum Coated Stranded Steel Core for Aluminum Conductors, Steel Reinforced (ACSR)

Standard:
ASTM B230,B231,B498 Standard

Code Name Size No./Dia.of Stranding Wires Approx. Overall Dia. Approx. Weight Code Name Size No./Dia.of Stranding Wires Approx. Overall Dia. Approx. Weight
AWG or MCM Aluminum Steel AWG or MCM Aluminum Steel
No./mm No./mm mm kg/km No./mm No./mm mm kg/km
Turkey 6 6/1.68 1/1.68 5.04 54 Starling 715.5 26/4.21 7/3.28 26.68 1466
Swan 4 6/2.12 1/2.12 6.36 85 Redwing 715.5 30/3.92 19/2.35 27.43 1653
Swanate 4 7/1.96 1/2.61 6.53 100 Tern 795.0 45/3.38 7/2.25 27.03 1333
Sparrow 2 6/2.67 1/2.67 8.01 136 Condor 795.0 54/3.08 7/3.08 27.72 1524
Sparate 2 7/2.47 1/3.30 8.24 159 Cuckoo 795.0 24/4.62 7/3.08 27.74 1524
Robin 1 6/3.00 1/3.00 9.00 171 Drake 795.0 26/4.44 7/3.45 28.11 1628
Raven 1/0 6/3.37 1/3.37 10.11 216 Coot 795.0 36/3.77 1/3.77 26.41 1198
Quail 2/0 6/3.78 1/3.78 11.34 273 Mallard 795.0 30/4.14 19/2.48 28.96 1838
Pigeon 3/0 6/4.25 1/4.25 12.75 343 Ruddy 900.0 45/3.59 7/2.40 28.73 1510
Penguin 4/0 6/4.77 1/4.77 14.31 433 Canary 900.0 54/3.28 7/3.28 29.52 1724
Waxwing 266.8 18/3.09 1/3.09 15.45 431 Rail 954.0 45/3.70 7/2.47 29.61 1601
Partridge 266.8 26/2.57 7/2.00 16.28 546 Catbird 954.0 36/4.14 1/4.14 28.95 1438
Ostrich 300.0 26/2.73 7/2.12 17.28 614 Cardinal 954.0 54/3.38 7/3.38 30.42 1829
Merlin 336.4 18/3.47 1/3.47 17.5 544 Ortlan 1033.5 45/3.85 7/2.57 30.81 1734
Linnet 336.4 26/2.89 7/2.25 18.31 689 Tanger 1033.5 36/4.30 1/4.30 30.12 1556
Oriole 336.4 30/2.69 7/2.69 18.83 784 Curlew 1033.5 54/3.52 7/3.52 31.68 1981
Chickadee 397.5 18/3.77 1/3.77 18.85 642 Bluejay 1113.0 45/4.00 7/2.66 31.98 1868
Brant 397.5 24/3.27 7/2.18 19.61 762 Finch 1113.0 54/3.65 19/2.19 32.85 2130
Ibis 397.5 26/3.14 7/2.44 19.88 814 Bunting 1192.5 45/4.14 7/2.76 33.12 2001
Lark 397.5 30/2.92 7/2.92 20.44 927 Grackle 1192.5 54/3.77 19/2.27 33.97 2282
Pelican 477.0 18/4.14 1/4.14 20.70 771 Bittern 1272.0 45/4.27 7/2.85 34.17 2134
Flicker 477.0 24/3.58 7/2.39 21.49 915 Pheasant 1272.0 54/3.90 19/2.34 35.10 2433
Hawk 477.0 26/3.44 7/2.67 21.79 978 Skylark 1272.0 36/4.78 1/4.78 33.42 1917
Hen 477.0 30/3.20 7/3.20 22.40 1112 Dipper 1351.5 45/4.40 7/2.92 35.16 2266
Osprey 556.5 18/4.47 1/4.47 22.35 899 Martin 1351.5 54/4.02 19/2.41 36.17 2585
Parakeet 556.5 24/3.87 7/2.58 23.22 1067 Bobolink 1431.0 45/4.53 7/3.02 36.24 2402
Dove 556.5 26/3.72 7/2.89 23.55 1140 Plover 1431.0 54/4.14 19/2.48 37.24 2738
Eagle 556.5 30/3.46 7/3.46 24.21 1298 Nuthatch 1510.5 45/4.65 7/3.10 37.20 2534
Peacock 605.0 24/4.03 7/2.69 24.20 1160 Parrot 1510.5 54/4.25 19/2.55 38.25 2890
Squab 605.0 26/3.87 7/3.01 24.51 1240 Lapwing 1590.0 45/4.77 7/3.18 38.16 2667
WoodDuck 605.0 30/3.61 7/3.61 25.25 1411 Falcon 1590.0 54/4.36 19/2.62 39.26 3042
Teal 605.0 30/3.61 19/2.16 25.24 1399 High Strength Stranding
Kingbird 636.0 18/4.78 1/4.78 23.88 1028 Grouse 80 8/2.54 1/4.24 9.32 222
Rook 636.0 24/4.14 7/2.76 24.84 1219 Petrel 101.8 12/2.34 7/2.34 11.71 378
Grosbeak 636.0 26/3.97 7/3.09 25.15 1302 Minorca 110.8 12/2.44 7/2.44 12.22 412
Scoter 636.0 30/3.70 7/3.70 25.88 1484 Leghorn 134.6 12/2.69 7/2.69 13.46 500
Egret 636.0 30/3.70 19/2.22 25.90 1470 Guinea 159 12/2.92 7/2.92 14.63 590
Swift 636.0 36/3.38 1/3.38 23.62 958 Dotterel 176.9 12/3.08 7/3.08 15.42 657
Flamingo 666.6 24/4.23 7/2.82 25.40 1278 Dorking 190.8 12/3.20 7/3.20 16.03 709
Gannet 666.6 26/4.07 7/3.16 25.76 1365 Brahma 203.2 16/2.86 19/2.48 18.14 1007
Stilt 715.5 24/4.39 7/2.92 26.31 1372 Cochin 211.3 12/3.37 7/3.37 16.84 785

Tags: , ,

Contact us

 

 

 

Success! Thanks for Your Request.
Error! Please Try Again.