Hot Sales 15kv Overhead ABC Cable
Prodotto in dettaglio
Informazioni di Base
Informazioni Aggiuntive.
Descrizione del prodotto
Hot Sales 15kv Overhead Abc Cable
Detailed Product Description
ABC cable
(Service drop cable)
1. Stranded aluminium conduct
2. PE or XLPE insulation
3. ACSR, AAAC Messenger wire
Application
It is preferred to use of service drop (ABC cables) instead of uninsulated conductors
At low voltage networks. Service drop (ABC cables)are especially used at areas
Where the cost of underground networks is expensive and also
For electrification of rural areas like villages.
Voltage
Rated voltage U0 / U = 0.6 /1 kV
VAC test voltage 5 kV
Technical Data
Maximum operating temperature 90 degree
Maximum short-circuit temperature 250 degree. Service drop( ABC cables) are especially used at areas where the cost of underground networks is expensive and also for electrification of rural areas like villages
Specification:
(1)Self-supporting
Phase | Phase | Phase | Approx.Overall Diameter | Max. D.C. Resistance of Conductor at 20ºC | |||
AAC+UV-XLPE | Compact Conductor | UV-XLPE Insulation | |||||
No.X Normal Cross Section of Cores | No.of Al Wires | Overall Diameter | Normal Thickness | Min. | Diameter | ||
No. X mm2 | – | mm | mm | mm | mm | mm | ohm/km |
1 X 10 | 7 | 4.05 | 1.0 | 0.8 | 6.05 | 6.05 | 3.08 |
1 X 16 | 7 | 4.8 | 1.2 | 0.98 | 7.2 | 7.20 | 1.91 |
1 X 25 | 7 | 6 | 1.2 | 0.98 | 8.4 | 8.40 | 1.20 |
1 X 35 | 7 | 7.0 | 1.4 | 1.16 | 9.8 | 9.80 | 0.868 |
1 X 50 | 7 | 8.3 | 1.4 | 1.16 | 11.1 | 11.10 | 0.641 |
1 X 70 | 19 | 9.8 | 1.4 | 1.16 | 12.6 | 12.60 | 0.443 |
1 X 95 | 19 | 11.6 | 1.6 | 1.34 | 14.8 | 14.80 | 0.320 |
1 X 120 | 19 | 13 | 1.6 | 1.34 | 16.2 | 16.20 | 0.253 |
1 X 150 | 19 | 14.6 | 1.8 | 1.52 | 18.2 | 18.20 | 0.206 |
1 X 185 | 36 | 16.2 | 2.0 | 1.70 | 20.2 | 20.20 | 0.164 |
1 X 240 | 36 | 18.4 | 2.2 | 1.88 | 22.8 | 22.80 | 0.125 |
2 X 10 | 7 | 4.05 | 1.0 | 0.8 | 6.05 | 12.10 | 3.08 |
2 X 16 | 7 | 4.8 | 1.2 | 0.98 | 7.2 | 14.40 | 1.91 |
2 X 25 | 7 | 6 | 1.2 | 0.98 | 8.4 | 16.80 | 1.20 |
2 X 35 | 7 | 7.0 | 1.4 | 1.16 | 9.8 | 19.60 | 0.868 |
2 X 50 | 7 | 8.3 | 1.4 | 1.16 | 11.1 | 22.20 | 0.641 |
2 X 70 | 19 | 9.8 | 1.4 | 1.16 | 12.6 | 25.20 | 0.443 |
2 X 95 | 19 | 11.6 | 1.6 | 1.34 | 14.8 | 29.60 | 0.320 |
2 X 120 | 19 | 13 | 1.6 | 1.34 | 16.2 | 32.40 | 0.253 |
2 X 150 | 19 | 14.6 | 1.8 | 1.52 | 18.2 | 36.40 | 0.206 |
2 X 185 | 36 | 16.2 | 2.0 | 1.70 | 20.2 | 40.40 | 0.164 |
2 X 240 | 36 | 18.4 | 2.2 | 1.88 | 22.8 | 45.60 | 0.125 |
3 X 10 | 7 | 4.05 | 1.0 | 0.8 | 6.05 | 13.07 | 3.08 |
3 X 16 | 7 | 4.8 | 1.2 | 0.98 | 7.2 | 15.55 | 1.91 |
3 X 25 | 7 | 6 | 1.2 | 0.98 | 8.4 | 18.14 | 1.20 |
3 X 35 | 7 | 7.0 | 1.4 | 1.16 | 9.8 | 21.17 | 0.868 |
3 X 50 | 7 | 8.3 | 1.4 | 1.16 | 11.1 | 23.98 | 0.641 |
3 X 70 | 19 | 9.8 | 1.4 | 1.16 | 12.6 | 27.22 | 0.443 |
3 X 95 | 19 | 11.6 | 1.6 | 1.34 | 14.8 | 31.97 | 0.320 |
3 X 120 | 19 | 13 | 1.6 | 1.34 | 16.2 | 34.99 | 0.253 |
3 X 150 | 19 | 14.6 | 1.8 | 1.52 | 18.2 | 39.31 | 0.206 |
3 X 185 | 36 | 16.2 | 2.0 | 1.70 | 20.2 | 43.63 | 0.164 |
3 X 240 | 36 | 18.4 | 2.2 | 1.88 | 22.8 | 49.25 | 0.125 |
4 X 10 | 7 | 4.05 | 1.0 | 0.8 | 6.05 | 14.64 | 3.08 |
4 X 16 | 7 | 4.8 | 1.2 | 0.98 | 7.2 | 17.42 | 1.91 |
4 X 25 | 7 | 6 | 1.2 | 0.98 | 8.4 | 20.33 | 1.20 |
4 X 35 | 7 | 7.0 | 1.4 | 1.16 | 9.8 | 23.72 | 0.868 |
4 X 50 | 7 | 8.3 | 1.4 | 1.16 | 11.1 | 26.86 | 0.641 |
4 X 70 | 19 | 9.8 | 1.4 | 1.16 | 12.6 | 30.49 | 0.443 |
4 X 95 | 19 | 11.6 | 1.6 | 1.34 | 14.8 | 35.82 | 0.320 |
4 X 120 | 19 | 13 | 1.6 | 1.34 | 16.2 | 39.20 | 0.253 |
4 X 150 | 19 | 14.6 | 1.8 | 1.52 | 18.2 | 44.04 | 0.206 |
4 X 185 | 36 | 16.2 | 2.0 | 1.70 | 20.2 | 48.88 | 0.164 |
4 X 240 | 36 | 18.4 | 2.2 | 1.88 | 22.8 | 55.18 | 0.125 |
(2) Phase + Neutral
Phase | Neutral | Phase | Neutral | Approx.Overall Diameter | Max. D.C. Resistance of Conductor at 20ºC | ||||
AAC+UV-XLPE | AAAC | Compact Conductor | UV-XLPE Insulation | Conductor | |||||
Phase | Neutral | ||||||||
No.X Normal Cross Section of Cores | No.X Normal Cross Section of Cores | No.of Al.Wire | Overall Dia. | Normal Thickness | Min. | No./Dia. of Al Alloy Wire | |||
No. X mm2 | No. X mm2 | – | mm | mm | Min. | No./mm | mm | ohm/km | ohm/km |
1 X 16 | 1 X 16 | 7 | 4.8 | 1.2 | 0.98 | 7/1.70 | 12.30 | 1.91 | 2.217 |
1 X 25 | 1 X 25 | 7 | 6 | 1.2 | 0.98 | 7/2.10 | 14.70 | 1.20 | 1.393 |
1 X 35 | 1 X 35 | 7 | 7.0 | 1.4 | 1.16 | 7/2.50 | 17.30 | 0.868 | 1.007 |
1 X 50 | 1 X 50 | 7 | 8.3 | 1.4 | 1.16 | 7/3.00 | 20.10 | 0.641 | 0.744 |
1 X 70 | 1 X 70 | 19 | 9.8 | 1.4 | 1.16 | 7/3.50 | 23.10 | 0.443 | 0.514 |
1 X 95 | 1 X 95 | 19 | 11.6 | 1.6 | 1.34 | 19/2.50 | 27.30 | 0.320 | 0.371 |
1 X 120 | 1 X 120 | 19 | 13 | 1.6 | 1.34 | 19/2.80 | 30.20 | 0.253 | 0.294 |
1 X 150 | 1 X 150 | 19 | 14.6 | 1.8 | 1.52 | 37/2.25 | 33.95 | 0.206 | 0.239 |
1 X 185 | 1 X 185 | 36 | 16.2 | 2.0 | 1.70 | 37/2.50 | 37.70 | 0.164 | 0.190 |
1 X 240 | 1 X 240 | 36 | 18.4 | 2.2 | 1.88 | 61/2.25 | 43.05 | 0.125 | 0.145 |
2 X 16 | 1 X 16 | 7 | 4.8 | 1.2 | 0.98 | 7/1.70 | 14.04 | 1.91 | 2.217 |
2 X 25 | 1 X 25 | 7 | 6 | 1.2 | 0.98 | 7/2.10 | 16.63 | 1.20 | 1.393 |
2 X 35 | 1 X 35 | 7 | 7.0 | 1.4 | 1.16 | 7/2.50 | 19.51 | 0.868 | 1.007 |
2 X 50 | 1 X 50 | 7 | 8.3 | 1.4 | 1.16 | 7/3.00 | 22.46 | 0.641 | 0.744 |
2 X 70 | 1 X 70 | 19 | 9.8 | 1.4 | 1.16 | 7/3.50 | 25.70 | 0.443 | 0.514 |
2 X 95 | 1 X 95 | 19 | 11.6 | 1.6 | 1.34 | 19/2.50 | 30.31 | 0.320 | 0.371 |
2 X 120 | 1 X 120 | 19 | 13 | 1.6 | 1.34 | 19/2.80 | 33.41 | 0.253 | 0.294 |
2 X 150 | 1 X 150 | 19 | 14.6 | 1.8 | 1.52 | 37/2.25 | 37.55 | 0.206 | 0.239 |
2 X 185 | 1 X 185 | 36 | 16.2 | 2.0 | 1.70 | 37/2.50 | 41.69 | 0.164 | 0.190 |
2 X 240 | 1 X 240 | 36 | 18.4 | 2.2 | 1.88 | 61/2.25 | 47.41 | 0.125 | 0.145 |
3 X 16 | 1 X 16 | 7 | 4.8 | 1.2 | 0.98 | 7/1.70 | 16.15 | 1.91 | 2.217 |
3 X 25 | 1 X 25 | 7 | 6 | 1.2 | 0.98 | 7/2.10 | 19.06 | 1.20 | 1.393 |
3 X 35 | 1 X 35 | 7 | 7.0 | 1.4 | 1.16 | 7/2.50 | 22.32 | 0.868 | 1.007 |
3 X 50 | 1 X 50 | 7 | 8.3 | 1.4 | 1.16 | 7/3.00 | 25.59 | 0.641 | 0.744 |
3 X 70 | 1 X 70 | 19 | 9.8 | 1.4 | 1.16 | 7/3.50 | 29.22 | 0.443 | 0.514 |
3 X 95 | 1 X 95 | 19 | 11.6 | 1.6 | 1.34 | 19/2.50 | 34.42 | 0.320 | 0.371 |
3 X 120 | 1 X 120 | 19 | 13 | 1.6 | 1.34 | 19/2.80 | 37.87 | 0.253 | 0.294 |
3 X 150 | 1 X 150 | 19 | 14.6 | 1.8 | 1.52 | 37/2.25 | 42.56 | 0.206 | 0.239 |
3 X 185 | 1 X 185 | 36 | 16.2 | 2.0 | 1.70 | 37/2.50 | 47.25 | 0.164 | 0.190 |
3 X 240 | 1 X 240 | 36 | 18.4 | 2.2 | 1.88 | 61/2.25 | 53.63 | 0.125 | 0.145 |
(3) Phase + Neutral + Service Connection
Phase | Neutral | Service Connection | Phase | Neutral | Service Connection | Approx.Overall Diameter of Bundled Cable | |||||
AAC+UV-XLPE | AAAC+UV-XLPE | AAC+UV-XLPE | Conductor | UV-XLPE | Conductor | UV-XLPE | Compact Conductor | UV-XLPE | |||
No.X Normal Cross Section of Cores | No.X Normal Cross Section of Cores | No.X Normal Cross Section of Cores | No. of Al. Wire | Overall Dia. | Normal Thickness |
No./Dia. of Al. Wire | Normal Thickness |
No. of Al. Wire | Overall Dia. | Normal Thickness |
|
No. X mm2 | No. X mm2 | No. X mm2 | – | mm | mm | mm | mm | No./mm | mm | mm | mm |
3 X 16 | 1 X 50 | 1 X 16 | 7 | 4.8 | 1.2 | 7/3.0 | 1.4 | 7 | 4.8 | 1.2 | 26.2 |
3 X 25 | 1 X 50 | 1 X 16 | 7 | 6 | 1.2 | 7/3.0 | 1.4 | 7 | 4.8 | 1.2 | 28.6 |
3 X 35 | 1 X 50 | 1 X 16 | 7 | 7.0 | 1.4 | 7/3.0 | 1.4 | 7 | 4.8 | 1.2 | 31.4 |
3 X 50 | 1 X 50 | 1 X 16 | 7 | 8.3 | 1.4 | 7/3.0 | 1.4 | 7 | 4.8 | 1.2 | 34 |
3 X 70 | 1 X 50 | 1 X 16 | 19 | 9.8 | 1.4 | 7/3.0 | 1.4 | 7 | 4.8 | 1.2 | 37 |
3 X 95 | 1 X 50 | 1 X 16 | 19 | 11.6 | 1.6 | 7/3.0 | 1.4 | 7 | 4.8 | 1.2 | 41.4 |
3 X 120 | 1 X 50 | 1 X 16 | 19 | 13 | 1.6 | 7/3.0 | 1.4 | 7 | 4.8 | 1.2 | 44.2 |
3 X 16 | 1 X 50 | 2 X 16 | 7 | 4.8 | 1.2 | 7/3.0 | 1.4 | 7 | 4.8 | 1.2 | 26.2 |
3 X 25 | 1 X 50 | 2 X 16 | 7 | 6 | 1.2 | 7/3.0 | 1.4 | 7 | 4.8 | 1.2 | 28.6 |
3 X 35 | 1 X 50 | 2 X 16 | 7 | 7.0 | 1.4 | 7/3.0 | 1.4 | 7 | 4.8 | 1.2 | 31.4 |
3 X 50 | 1 X 50 | 2 X 16 | 7 | 8.3 | 1.4 | 7/3.0 | 1.4 | 7 | 4.8 | 1.2 | 34 |
3 X 70 | 1 X 50 | 2 X 16 | 19 | 9.8 | 1.4 | 7/3.0 | 1.4 | 7 | 4.8 | 1.2 | 37 |
3 X 95 | 1 X 50 | 2 X 16 | 19 | 11.6 | 1.6 | 7/3.0 | 1.4 | 7 | 4.8 | 1.2 | 41.4 |
3 X 120 | 1 X 50 | 2 X 16 | 19 | 13 | 1.6 | 7/3.0 | 1.4 | 7 | 4.8 | 1.2 | 44.2 |
- Next: 11kv XLPE Insulated Copper Core PVC Sheathed Cable
- Previous: Copper Core Steel Wire Armoured Power Cable
Contact us
Simile o correlato
- No related articles