Type URD Cable-Aluminum Conductor
Construction
Concentric stranded or compressed 1350-H19 aluminum conductors, crosslinked polyethylene insulation. Insulated conductors surface printed, neutral triple yellow striped. Two phase and one neutral conductor twisted together (LH lay) or parallel if so specified. Black neutrals may be specified if desired.
Standards
ASTM B-230, B-231 and ICEA S-66-524 UL Standard 854 for Type USE Federal Specification JC-30B NEC
Code name |
Phase conductor | Neutral | Single phase conductor (in) | Outside diameter (in) |
Weight per 1000ft (lbs) |
Ampacity | |||||
Size AWG |
Strand |
Insulation thickness (mls) |
Size AWG |
Strand |
Insulation thickness(mls) | Direct burial | In duct | ||||
Erksine | 6 | 7/w | 60 | 6 | 7/w | 60 | .299 | .646 | 143 | 95 | 70 |
Vassar | 4 | 7/w | 60 | 4 | 7/w | 60 | .345 | .754 | 203 | 125 | 90 |
Stephens | 2 | 7/w | 60 | 4 | 7/w | 60 | .403 | .842 | 264 | 165 | 120 |
Ramapo | 2 | 7/w | 60 | 2 | 7/w | 60 | .403 | .874 | 294 | 165 | 120 |
Brenau | 1/0 | 19/w | 80 | 2 | 7/w | 60 | .522 | 1.064 | 408 | 215 | 160 |
Bergen | 1/0 | 19/w | 80 | 1/0 | 19/w | 80 | .522 | 1.133 | 465 | 215 | 160 |
Converse | 2/0 | 19/w | 80 | 1 | 19/w | 80 | .566 | 1.174 | 502 | 245 | 180 |
Hunter | 2/0 | 19/w | 80 | 2/0 | 19/w | 80 | .566 | 1.228 | 560 | 245 | 180 |
Hollins | 3/0 | 19/w | 80 | 1/0 | 19/w | 80 | .616 | 1.276 | 606 | 280 | 205 |
Rockland | 3/0 | 19/w | 80 | 3/0 | 19/w | 80 | .616 | 1.336 | 678 | 280 | 205 |
Sweetbriar | 4/0 | 19/w | 80 | 2/0 | 19/w | 80 | .672 | 1.389 | 739 | 315 | 240 |
Monmouth | 4/0 | 19/w | 80 | 4/0 | 19/w | 80 | .672 | 1.457 | 828 | 315 | 240 |
Pratt | 250 | 37/w | 95 | 3/0 | 19/w | 80 | .748 | 1.538 | 893 | 345 | 265 |
Wesleyan | 350 | 37/w | 95 | 4/0 | 19/w | 80 | .851 | 1.736 | 1166 | 415 | 320 |
Holyoke | 500 | 37/w | 95 | 300 | 37/w | 95 | .979 | 2.008 | 1607 | 495 | 395 |
Rider | 500 | 37/w | 95 | 350 | 37/w | 95 | .979 | 2.035 | 1663 | 495 | 395 |
Fairfield | 750 | 61/w | 110 | 500 | 37/w | 95 | 1.188 | 2.086 | 2304 | 615 | 525 |
Ampacity: 90ºC conductor temperature, 20ºC ambient, RHO 50, 100% load factor for three conductor triplex with neutral carrying only unbalanced load. Technical data for cable with solid black neutral is identical to yellow extruded stripe data. All yellow extruded stripe cable is XLP insulation
To determine correct ampacity by conductor size, please consult the National Electric Code, latest edition. Packaging: Available 500 ft reels, 1,000 ft reels and longer lengths.
The above data are approximate and subject to normal manufacturing tolerances.
0.6/1KV Self support conductor abc cable, aerial bundle cable,
We can supply this conductor according to different recognized standards, such as IEC Standard, ANSI/ICEA , NFC, NBR, ITP ,customer special specification also can be satisfied.
Application: ABC cable Conllie, duplex cable, service drop, overhead cable.
The basic construction is as following:
Aerial Bundle Conductor-ABC(South Africa Standard Sizes)-SANS 1418-1
Table 01
Type of conductor or core | Norminal cross-sectional area mm2 | Nubmer of wires Min. |
Diameter of conductormm | Resistanceat 20ºC Ω/km Max. | Breaking force(N) | Thickness of insulation (mm) | Outer diameter of core(mm) | |||
Min. | Max. | Min. | Average | Min. | Min. | Max. | ||||
Phase or auxiliary or non-strain-bearing netural(aluminium) | +16 | 6 | 4.6 | 5.1 | 1.91 | 2070 | 1.2 | 0.98 | 7.0 | 7.8 |
25 | 6 | 5.8 | 6.3 | 1.2 | 3300 | 1.4 | 1.16 | 8.6 | 9.4 | |
35 | 6 | 6.8 | 7.3 | 0.868 | 4500 | 1.6 | 1.34 | 10.0 | 10.9 | |
50 | 6 | 7.9 | 8.4 | 0.641 | 6200 | 1.6 | 1.34 | 11.1 | 12.0 | |
70 | 12 | 9.7 | 10.2 | 0.443 | 8900 | 1.8 | 1.52 | 13.3 | 14.2 | |
95 | 15 | 11.0 | 12.0 | 0.320 | 12300 | 1.8 | 1.52 | 14.6 | 16.0 | |
120 | 15 | 12.5 | 13.5 | 0.253 | 15600 | 1.8 | 1.52 | 16.3 | 17.5 | |
150 | 15 | 13.9 | 15.0 | 0.206 | 19200 | 1.8 | 1.52 | 17.1 | 18.6 | |
Service connection(aluminium) | 16 | 6 | 4.6 | 5.2 | 1.91 | 2070 | 1.2 | 0.98 | 7.0 | 8.0 |
25 | 6 | 5.6 | 6.5 | 1.2 | 3300 | 1.4 | 1.16 | 8.6 | 9.6 | |
Service connection(copper) | 10 | 6 | – | 4.2 | 1.83 | 3600 | 1.2 | 0.98 | 6.2 | 7.0 |
16 | 6 | – | 5.3 | 1.15 | 5760 | 1.2 | 0.98 | 7.2 | 8.0 | |
25 | 6 | – | 6.6 | 0.727 | 8750 | 1.4 | 1.16 | 8.6 | 9.6 | |
Number and nominal diameter of wires mm |
||||||||||
Supporting core(aluminium alloy) |
54.6 | 7×3.15 | 9.2 | 9.6 | 0.630 | 16600 | 1.6 | 1.34 | 12.3 | 13.0 |
70 | 7×3.50 | 10.0 | 10.4 | 0.500 | 20100 | 1.6 | 1.34 | 12.9 | 13.6 | |
+Auxiliary conductors or cores only |
When a supporting core is specified in a tender invitation,the combinations listed in Table 02 below:
Table 02
1 | 2 |
Nominal cross sectional area of supporting conductor mm2 | Nominal cross-sectional areas of phase conductors mm2 |
54.6 | 25,35,50,70,95 |
70 | 70,95,120 |
95 | 95,120,150 |
Aerial Bundle Conductor-ABC(South Africa Custimized Size Specification)
Table 03
Type of conductor or core | Norminal cross-sectional area mm2 | Nubmer of wires | Diameter of conductormm | Resistanceat 20ºC Ω/km Max. | Breaking force(N) | Thickness of insulation (mm) | Outer diameter of core(mm) | |||
Min. | Max. | Min. | Average | Min. | Min. | Max. | ||||
Phase or auxiliary or non-strain-bearing netural(aluminium) | 16 | 7/1.65 | 4.6 | 5.1 | 1.91 | 2070 | 1.2 | 0.98 | 7.0 | 7.8 |
25 | 7/2.15 | 5.8 | 6.3 | 1.2 | 3300 | 1.4 | 1.16 | 8.6 | 9.4 | |
35 | 7/2.55 | 6.8 | 7.3 | 0.868 | 4500 | 1.6 | 1.34 | 10.0 | 10.9 | |
50 | 7/2.99 | 7.9 | 8.4 | 0.641 | 6200 | 1.6 | 1.34 | 11.1 | 12.0 | |
70 | 14/2.59 | 9.7 | 10.2 | 0.443 | 8900 | 1.8 | 1.52 | 13.3 | 14.2 | |
95 | 19/2.59 | 11.0 | 12.0 | 0.320 | 12300 | 1.8 | 1.52 | 14.6 | 16.0 | |
120 | 19/2.99 | 12.5 | 13.5 | 0.253 | 15600 | 1.8 | 1.52 | 16.3 | 17.5 | |
150 | 30/2.59 | 13.9 | 15.0 | 0.206 | 19200 | 1.8 | 1.52 | 17.1 | 18.6 | |
Service connection(aluminium) | 16 | 7/1.65 | 4.6 | 5.2 | 1.91 | 2070 | 1.2 | 0.98 | 7.0 | 8.0 |
25 | 7/2.15 | 5.6 | 6.5 | 1.2 | 3300 | 1.4 | 1.16 | 8.6 | 9.6 | |
Service connection(copper) | 10 | 7/1.35 | – | 4.2 | 1.83 | 3600 | 1.2 | 0.98 | 6.2 | 7.0 |
16 | 7/1.69 | – | 5.3 | 1.15 | 5760 | 1.2 | 0.98 | 7.2 | 8.0 | |
25 | 7/2.19 | – | 6.6 | 0.727 | 8750 | 1.4 | 1.16 | 8.6 | 9.6 | |
Supporting core(aluminium alloy) | 16 | 7/1.71 | 5.1 | 5.2 | 2.053 | 5070 | 1.4 | 1.16 | 7.9 | 8.0 |
25 | 7/2.15 | 6.4 | 6.5 | 1.314 | 8000 | 1.4 | 1.16 | 9.2 | 9.3 | |
35 | 7/2.48 | 6.6 | 7.5 | 0.986 | 10300 | 1.6 | 1.34 | 10.7 | 10.8 | |
50 | 7/2.89 | 7.7 | 8.4 | 0.720 | 14200 | 1.6 | 1.34 | 11.9 | 12.0 | |
54.6 | 7/3.15 | 9.2 | 9.6 | 0.630 | 16600 | 1.6 | 1.34 | 12.3 | 13.0 | |
70 | 7/3.50 | 10.0 | 10.4 | 0.500 | 20100 | 1.6 | 1.34 | 12.9 | 13.6 |