Low Voltage 0.6/1kv ABC Cable for Overhead Use
Prodotto in dettaglio
Informazioni di Base
Informazioni Aggiuntive.
Descrizione del prodotto
Low Voltage 0.6/1KV ABC Cable For Overhead Use
Aerial insulated cable consists of copper or aluminum conductor, inner shielding layer, weather-poof insulation material and outer shielding layer.It has not only power-transmitting character of power cable, but strong mechanical character of aerial cable as well.
The product is manufactured according to the standards of GB14049Aerial insulated cables of rated voltages 10 KV and 35KV and IEC60502Extruded solid dielectric power cables for rated voltages from 1KV to 30KV.
10KV Rated Voltage Insulated Aerial Cable:
1.Suitable use for AC rated voltage 10KV (U) or 12KV(Um) overhead power transmission lines.
2.The installation temperature should be not less than -20.
3.The maximum temperature of conductor:XLPE insulated cable is 250 when the short-circuit period should not exceed 5 seconds.
4.The maximum permissible continuous operating temperature of conductor:A.Cable with bearing structure:XLPE insulated cable is 90;B.Cable without bearing structure:Considering no stipulation in GB, it should be under above a value according to the real instance.
5.The permission bending radius is no less than:A.Of single core cable is 20(D+d) ±5% mm, TR structure is 20Dmm;B.Of multi-core cable is 15(D+d) ±5% mm.
Type
Name
Main Usage
JKV
Copper conductor PVC insulated aerial cables
The cables fit for overhead fixed-installation, service line and so on.
JKLV
Aluminum conductor PVC insulated aerial cables
JKY
Copper conductor PE insulated aerial cables
JKLY
Aluminum conductor PE insulated aerial cables
JKYJ
Copper conductor XLPE insulated aerial cables
JKLYJ
Aluminum conductor XLPE insulated aerial cables
JKLGV
ACSR conductor PVC insulated aerial cables
JKLGY
ACSR conductor PE insulated aerial cables
JKLGYJ
ACSR conductor XLPE insulated aerial cables
Specification:
(1)Self-supporting | |||||||||||
Phase | Phase | Phase | Approx.Overall Diameter | Min.Bending Radius | Max. D.C. Resistance of Conductor at 20 | ||||||
AAC+UV-XLPE | Compact Conductor | UV-XLPE Insulation | |||||||||
No.X Normal Cross Section of Cores | No.of Al Wires | Overall Diameter | Thickness | Min. | Diameter | ||||||
No. X mm 2 | – | mm | mm | mm | mm | mm | kN | ohm/km | |||
4 X 16 | 7 | 4.8 | 1.2 | 0.98 | 7.2 | 17.42 | 2.07 | 1.91 | |||
4 X 25 | 7 | 6 | 1.4 | 1.16 | 8.8 | 21.3 | 3.3 | 1.2 | |||
4 X 35 | 7 | 7 | 1.6 | 1.34 | 10.2 | 24.68 | 4.5 | 0.868 | |||
4 X 50 | 7 | 8.3 | 1.6 | 1.34 | 11.5 | 27.83 | 6.2 | 0.641 | |||
4 X 70 | 19 | 10 | 1.8 | 1.52 | 13.6 | 32.91 | 8.9 | 0.443 | |||
4 X 95 | 19 | 11.6 | 1.8 | 1.52 | 15.2 | 36.78 | 12.3 | 0.32 | |||
4 X 120 | 19 | 13 | 1.8 | 1.52 | 16.6 | 40.17 | 15.6 | 0.253 | |||
4 X 150 | 19 | 14.6 | 1.8 | 1.52 | 18.2 | 44.04 | 19.2 | 0.206 | |||
3 X 16 | 7 | 4.8 | 1.2 | 0.98 | 7.2 | 15.55 | 2.07 | 1.91 | |||
3 X 25 | 7 | 6 | 1.4 | 1.16 | 8.8 | 19.01 | 3.3 | 1.2 | |||
3 X 35 | 7 | 7 | 1.6 | 1.34 | 10.2 | 22.03 | 4.5 | 0.868 | |||
3 X 50 | 7 | 8.3 | 1.6 | 1.34 | 11.5 | 24.84 | 6.2 | 0.641 | |||
3 X 70 | 19 | 10 | 1.8 | 1.52 | 13.6 | 29.38 | 8.9 | 0.443 | |||
3 X 95 | 19 | 11.6 | 1.8 | 1.52 | 15.2 | 32.83 | 12.3 | 0.32 | |||
3 X 120 | 19 | 13 | 1.8 | 1.52 | 16.6 | 35.86 | 15.6 | 0.253 | |||
3 X 150 | 19 | 14.6 | 1.8 | 1.52 | 18.2 | 39.31 | 19.2 | 0.206 | |||
2 X 16 | 7 | 4.8 | 1.2 | 0.98 | 7.2 | 14.4 | 2.07 | 1.91 | |||
2 X 25 | 7 | 6 | 1.4 | 1.16 | 8.8 | 17.6 | 3.3 | 1.2 | |||
2 X 35 | 7 | 7 | 1.6 | 1.34 | 10.2 | 20.4 | 4.5 | 0.868 | |||
2 X 50 | 7 | 8.3 | 1.6 | 1.34 | 11.5 | 23 | 6.2 | 0.641 | |||
2 X 70 | 19 | 10 | 1.8 | 1.52 | 13.6 | 27.2 | 8.9 | 0.443 | |||
2 X 95 | 19 | 11.6 | 1.8 | 1.52 | 15.2 | 30.4 | 12.3 | 0.32 | |||
2 X 120 | 19 | 13 | 1.8 | 1.52 | 16.6 | 33.2 | 15.6 | 0.253 | |||
2 X 150 | 19 | 14.6 | 1.8 | 1.52 | 18.2 | 36.4 | 19.2 | 0.206 | |||
1 X 16 | 7 | 4.8 | 1.2 | 0.98 | 7.2 | 7.2 | 2.07 | 1.91 | |||
1 X 25 | 7 | 6 | 1.4 | 1.16 | 8.8 | 8.8 | 3.3 | 1.2 | |||
1 X 35 | 7 | 7 | 1.6 | 1.34 | 10.2 | 10.2 | 4.5 | 0.868 | |||
1 X 50 | 7 | 8.3 | 1.6 | 1.34 | 11.5 | 11.5 | 6.2 | 0.641 | |||
1 X 70 | 19 | 10 | 1.8 | 1.52 | 13.6 | 13.6 | 8.9 | 0.443 | |||
1 X 95 | 19 | 11.6 | 1.8 | 1.52 | 15.2 | 15.2 | 12.3 | 0.32 | |||
1 X 120 | 19 | 13.01 | 1.8 | 1.52 | 16.6 | 16.6 | 15.6 | 0.253 | |||
1 X 150 | 19 | 14.6 | 1.8 | 1.52 | 18.2 | 18.2 | 19.2 | 0.206 | |||
(2) Phase + Supporting | |||||||||||
Phase | Supporting | Phase | Supporting | Approx. Overall Diameter | |||||||
AAC+UV-XLPE | AAAC+UV-XLPE | Compact Conductor | UV-XLPE Insulation | Conductor | UV-XLPE Insulation | ||||||
No.X Normal Cross Section of Cores | No.X Normal Cross Section of Cores | No.of Al Wires | Overall Diameter | Normal Thickness | No./Dia.of Al. Wire | Normal Thickness | |||||
No. X mm 2 | No. X mm 2 | – | mm | mm | No./mm | mm | mm | ||||
3 X 16 | 1 X 54.6 | 7 | 4.8 | 1.2 | 7/3.15 | 1.6 | 20.72 | ||||
3 X 25 | 1 X 54.6 | 7 | 6 | 1.4 | 7/3.15 | 1.6 | 23.63 | ||||
3 X 35 | 1 X 54.6 | 7 | 7 | 1.6 | 7/3.15 | 1.6 | 26.17 | ||||
3 X 50 | 1 X 54.6 | 7 | 8.3 | 1.6 | 7/3.15 | 1.6 | 28.53 | ||||
3 X 70 | 1 X 54.6 | 19 | 10 | 1.8 | 7/3.15 | 1.6 | 32.34 | ||||
3 X 95 | 1 X 54.6 | 19 | 11.6 | 1.8 | 7/3.15 | 1.6 | 35.24 | ||||
3 X 120 | 1 X 54.6 | 19 | 13 | 1.8 | 7/3.15 | 1.6 | 37.78 | ||||
3 X 150 | 1 X 54.6 | 19 | 14.6 | 1.8 | 7/3.15 | 1.6 | 40.69 | ||||
3 X 16 | 1 X 70 | 7 | 4.8 | 1.2 | 7/3.5 | 1.6 | 21.36 | ||||
3 X 25 | 1 X 70 | 7 | 6 | 1.4 | 7/3.5 | 1.6 | 24.26 | ||||
3 X 35 | 1 X 70 | 7 | 7 | 1.6 | 7/3.5 | 1.6 | 26.8 | ||||
3 X 50 | 1 X 70 | 7 | 8.3 | 1.6 | 7/3.5 | 1.6 | 29.16 | ||||
3 X 70 | 1 X 70 | 19 | 10 | 1.8 | 7/3.5 | 1.6 | 32.97 | ||||
3 X 95 | 1 X 70 | 19 | 11.6 | 1.8 | 7/3.5 | 1.6 | 35.88 | ||||
3 X 120 | 1 X 70 | 19 | 13 | 1.8 | 7/3.5 | 1.6 | 38.42 | ||||
3 X 150 | 1 X 70 | 19 | 14.6 | 1.8 | 7/3.5 | 1.6 | 41.32 | ||||
3) Phase+Supporting+ Service Connection | |||||||||||
Phase | Supporting | Service Connection | Phase | Supporting | Service Connection | Approx.Overall Diameter of Bundled Cable | |||||
AAC+UV-XLPE | AAAC+UV-XLPE | AAC+UV-XLPE | Compact Conductor | UV-XLPE | Conductor | UV-XLPE | Compact Conductor | UV-XLPE | |||
No.X Normal Cross Section of Cores | No.X Normal Cross Section of Cores | No.X Normal Cross Section of Cores | No.of Al.Wire | Overall Dia. | Normal | No./Dia.of Al. Wire | Normal | No. of Al. Wire | Overall Dia. | Normal | |
Thickness | Thickness | Thickness | |||||||||
No. X mm 2 | No. X mm 2 | No. X mm 2 | – | mm | mm | No./mm | mm | – | mm | mm | mm |
3 X 16 | 1 X 54.6 | 1 X 25 | 7 | 4.8 | 1.2 | 7/3.15 | 1.6 | 7 | 6 | 1.4 | 27.05 |
3 X 25 | 1 X 54.6 | 1 X 25 | 7 | 6 | 1.4 | 7/3.15 | 1.6 | 7 | 6 | 1.4 | 30.25 |
3 X 35 | 1 X 54.6 | 1 X 25 | 7 | 7 | 1.6 | 7/3.15 | 1.6 | 7 | 6 | 1.4 | 33.05 |
3 X 50 | 1 X 54.6 | 1 X 25 | 7 | 8.3 | 1.6 | 7/3.15 | 1.6 | 7 | 6 | 1.4 | 35.65 |
3 X 70 | 1 X 54.6 | 1 X 25 | 19 | 10 | 1.8 | 7/3.15 | 1.6 | 7 | 6 | 1.4 | 39.85 |
3 X 95 | 1 X 54.6 | 1 X 25 | 19 | 11.6 | 1.8 | 7/3.15 | 1.6 | 7 | 6 | 1.4 | 43.05 |
3 X 120 | 1 X 54.6 | 1 X 25 | 19 | 13 | 1.8 | 7/3.15 | 1.6 | 7 | 6 | 1.4 | 45.85 |
3 X 150 | 1 X 54.6 | 1 X 25 | 19 | 14.6 | 1.8 | 7/3.15 | 1.6 | 7 | 6 | 1.4 | 49.05 |
3 X 16 | 1 X 54.6 | 2 X 25 | 7 | 4.8 | 1.2 | 7/3.15 | 1.6 | 7 | 6 | 1.4 | 27.05 |
3 X 25 | 1 X 54.6 | 2 X 25 | 7 | 6 | 1.4 | 7/3.15 | 1.6 | 7 | 6 | 1.4 | 30.25 |
3 X 35 | 1 X 54.6 | 2 X 25 | 7 | 7 | 1.6 | 7/3.15 | 1.6 | 7 | 6 | 1.4 | 33.05 |
3 X 50 | 1 X 54.6 | 2 X 25 | 7 | 8.3 | 1.6 | 7/3.15 | 1.6 | 7 | 6 | 1.4 | 35.65 |
3 X 70 | 1 X 54.6 | 2 X 25 | 19 | 10 | 1.8 | 7/3.15 | 1.6 | 7 | 6 | 1.4 | 39.85 |
3 X 95 | 1 X 54.6 | 2 X 25 | 19 | 11.6 | 1.8 | 7/3.15 | 1.6 | 7 | 6 | 1.4 | 43.05 |
3 X 120 | 1 X 54.6 | 2 X 25 | 19 | 13 | 1.8 | 7/3.15 | 1.6 | 7 | 6 | 1.4 | 45.85 |
3 X 150 | 1 X 54.6 | 2 X 25 | 19 | 14.6 | 1.8 | 7/3.15 | 1.6 | 7 | 6 | 1.4 | 49.05 |
FAQ
1.How many years has Henan Jiapu Cable Group been in production?
Founded in October 1998 by Mr.Gu, our facility has three separate manufacturing workshops within its 100,000-sq.-ft.Building.In 2012, we operates in a new 666,000 sq.Foot state-of-the-art facility in Xiaodian Industry Park.,Xinxiang, Henan ,China
2.What kinds of products does Jiapu Cable manufacture?
1)Bare Conductor ,such as AAC,AAAC,ACSR,ACAR,AACSR,ACSR/AW and so on;
2)Aerial Bundled Cable (1kV-35kV ),such as Duplex,Triplex,Quadruplex Drop Wires and so on;
3)PVC Insulated (Flexible ) Wire ;
4) PVC Insulated and Sheathed (Armoured) Power Cable;
5)Low, Medium, High Voltage (1kV-220kV) XLPE Insulated (Armoured) Power Cable;
6)Welding Cable, Control Cable, Concentric Cable, Rubber Sheathed Cable and so on;
3.What kind of certifications do you have?
SABS, CE, ISO9001-2000, SGS
4.Which markets do you involve mainly in?
Our products have been exported mainly to Africa, Middle East, South-east Asia, South America,Central America,North America, Europe ,Australia, etc.
5.Which standards do you comply with when you produce the electrical wires and cables ?
We are able to produce electrical wires and cables based on GB, JB, IEC, BS, DIN, ASTM, JIS, NF, AS/NZS, CSA, etc.Meanwhile, we can design and manufacture the cables according to the samples and technical specification the customer supply.
6.What is the min.Order quantity ?
It depends on the type and size of electrical wires and cables.For some small electrical wires, 100 meters can be accepted .But for the power cables with medium or high voltage, that should comply with the property of installed equipments.Anyhow,we will try our best to solve the problem and meet with the requirement If you have special request.
7.What is the production capacity per week or per month ?
For the bare conductor, we can finish 3000 tons within one month.For power cables, that depends on the type and size.The total output value per month is approx.USD3,000,000.00 for insulated aluminum cables and that is approx.USD8,000,000.00 for insulated copper cables.