High Quality ABC Aerial Bundled Cable for Sale
Prodotto in dettaglio
Informazioni di Base
Informazioni Aggiuntive.
Descrizione del prodotto
High Quality ABC Aerial Bundled Cable For Sale
1. Features
RUS accepted.
Extruded ridges for easy Phase identification.
2. Standards
ICEA S-76-474
Neutral-Supported Power Cable Assemblies with Weather-Resistant Extruded Insulated rated 600V.
3. Application
For overhead distribution of electrical energy, such as a supply power, from pole-mounted transformer to the user’s service head where connection to the service entrance cable is made.
Also for temporary services and street light installations.
4. Specification
Maximum operating voltage: 600 volts, Maximum conductor operation temperatures:
Wet and dry locations:
Normal: 90° C
Emergency: 130° C
Short Circuit: 250° C
5. Engineering Information
Conductor: Aluminum alloy 1350-H19, solid conductor per ASTM B230, Compressed Class B stranding, or Class A stranding or unilay-compressed per ASTM B231, or combination unilay (19 wires)Per ASTM B786. Upon Request: Copper Conductors.
Separator: Suitable opaque tape as required.
Insulation: Black thermoset croos-linked polyethylene (XLPE). Upon request: PE insulated.
Neutral: Bare aluminum alloy 1350-H19 classes A stranding per ASTM B231 or ACSR stranding per ASTM B232, or ACSR/AW per ASTM B549. Upon request cover neutral.
Conductor Phase ID: Extruded ridges.
Duplex: Consist of one black phase insulated conductor twisted around a bare neutral conductor
Specification:
(2) Phase + Messenger | |||||||||||
Phase | Messenger | Phase | Messenger | Approx.Overall Diameter | Max. D.C. Resistance of Conductor at 20 Centgrade | ||||||
AAC+UV-XLPE | AAAC | Compact Conductor | UV-XLPE Insulation | Conductor | |||||||
Phase | Messenger | ||||||||||
No.X Normal Cross Section of Cores | No.X Normal Cross Section of Cores | No.of Al.Wire | Overall Dia. | Normal Thickness | Min. | No./Dia. of Al Alloy Wire | |||||
No. X mm 2 | No. X mm 2 | – | mm | mm | Min. | No./mm | mm | ohm/km | ohm/km | ||
1 X 16 | 1 X 16 | 7 | 4.8 | 1.2 | 0.98 | 7/1.70 | 12.3 | 1.91 | 2.217 | ||
1 X 25 | 1 X 25 | 7 | 6 | 1.2 | 0.98 | 7/2.10 | 14.7 | 1.2 | 1.393 | ||
1 X 35 | 1 X 35 | 7 | 7 | 1.4 | 1.16 | 7/2.50 | 17.3 | 0.868 | 1.007 | ||
1 X 50 | 1 X 50 | 7 | 8.3 | 1.4 | 1.16 | 7/3.00 | 20.1 | 0.641 | 0.744 | ||
1 X 70 | 1 X 70 | 19 | 9.8 | 1.4 | 1.16 | 7/3.50 | 23.1 | 0.443 | 0.514 | ||
1 X 95 | 1 X 95 | 19 | 11.6 | 1.6 | 1.34 | 19/2.50 | 27.3 | 0.32 | 0.371 | ||
1 X 120 | 1 X 120 | 19 | 13 | 1.6 | 1.34 | 19/2.80 | 30.2 | 0.253 | 0.294 | ||
1 X 150 | 1 X 150 | 19 | 14.6 | 1.8 | 1.52 | 37/2.25 | 33.95 | 0.206 | 0.239 | ||
1 X 185 | 1 X 185 | 36 | 16.2 | 2 | 1.7 | 37/2.50 | 37.7 | 0.164 | 0.19 | ||
1 X 240 | 1 X 240 | 36 | 18.4 | 2.2 | 1.88 | 61/2.25 | 43.05 | 0.125 | 0.145 | ||
2 X 16 | 1 X 16 | 7 | 4.8 | 1.2 | 0.98 | 7/1.70 | 14.04 | 1.91 | 2.217 | ||
2 X 25 | 1 X 25 | 7 | 6 | 1.2 | 0.98 | 7/2.10 | 16.63 | 1.2 | 1.393 | ||
2 X 35 | 1 X 35 | 7 | 7 | 1.4 | 1.16 | 7/2.50 | 19.51 | 0.868 | 1.007 | ||
2 X 50 | 1 X 50 | 7 | 8.3 | 1.4 | 1.16 | 7/3.00 | 22.46 | 0.641 | 0.744 | ||
2 X 70 | 1 X 70 | 19 | 9.8 | 1.4 | 1.16 | 7/3.50 | 25.7 | 0.443 | 0.514 | ||
2 X 95 | 1 X 95 | 19 | 11.6 | 1.6 | 1.34 | 19/2.50 | 30.31 | 0.32 | 0.371 | ||
2 X 120 | 1 X 120 | 19 | 13 | 1.6 | 1.34 | 19/2.80 | 33.41 | 0.253 | 0.294 | ||
2 X 150 | 1 X 150 | 19 | 14.6 | 1.8 | 1.52 | 37/2.25 | 37.55 | 0.206 | 0.239 | ||
2 X 185 | 1 X 185 | 36 | 16.2 | 2 | 1.7 | 37/2.50 | 41.69 | 0.164 | 0.19 | ||
2 X 240 | 1 X 240 | 36 | 18.4 | 2.2 | 1.88 | 61/2.25 | 47.41 | 0.125 | 0.145 | ||
3 X 16 | 1 X 16 | 7 | 4.8 | 1.2 | 0.98 | 7/1.70 | 16.15 | 1.91 | 2.217 | ||
3 X 25 | 1 X 25 | 7 | 6 | 1.2 | 0.98 | 7/2.10 | 19.06 | 1.2 | 1.393 | ||
3 X 35 | 1 X 35 | 7 | 7 | 1.4 | 1.16 | 7/2.50 | 22.32 | 0.868 | 1.007 | ||
3 X 50 | 1 X 50 | 7 | 8.3 | 1.4 | 1.16 | 7/3.00 | 25.59 | 0.641 | 0.744 | ||
3 X 70 | 1 X 70 | 19 | 9.8 | 1.4 | 1.16 | 7/3.50 | 29.22 | 0.443 | 0.514 | ||
3 X 95 | 1 X 95 | 19 | 11.6 | 1.6 | 1.34 | 19/2.50 | 34.42 | 0.32 | 0.371 | ||
3 X 120 | 1 X 120 | 19 | 13 | 1.6 | 1.34 | 19/2.80 | 37.87 | 0.253 | 0.294 | ||
3 X 150 | 1 X 150 | 19 | 14.6 | 1.8 | 1.52 | 37/2.25 | 42.56 | 0.206 | 0.239 | ||
3 X 185 | 1 X 185 | 36 | 16.2 | 2 | 1.7 | 37/2.50 | 47.25 | 0.164 | 0.19 | ||
3 X 240 | 1 X 240 | 36 | 18.4 | 2.2 | 1.88 | 61/2.25 | 53.63 | 0.125 | 0.145 | ||
(3) Phase + Neutral + Service Connection | |||||||||||
Phase | Neutral | Service Connection | Phase | Neutral | Service Connection | Approx.Overall Diameter of Bundled Cable | |||||
AAC+UV-XLPE | AAAC+UV-XLPE | AAC+UV-XLPE | Conductor | UV-XLPE | Conductor | UV-XLPE | Compact Conductor | UV-XLPE | |||
No.X Normal Cross Section of Cores | No.X Normal Cross Section of Cores | No.X Normal Cross Section of Cores | No. of Al. Wire | Overall Dia. | Normal | No./Dia. of Al. Wire | Normal | No. of Al. Wire | Overall Dia. | Normal | |
Thickness | Thickness | Thickness | |||||||||
No. X mm 2 | No. X mm 2 | No. X mm 2 | – | mm | mm | mm | mm | No./mm | mm | mm | mm |
3 X 16 | 1 X 50 | 1 X 16 | 7 | 4.8 | 1.2 | 7/3.0 | 1.4 | 7 | 4.8 | 1.2 | 26.2 |
3 X 25 | 1 X 50 | 1 X 16 | 7 | 6 | 1.2 | 7/3.0 | 1.4 | 7 | 4.8 | 1.2 | 28.6 |
3 X 35 | 1 X 50 | 1 X 16 | 7 | 7 | 1.4 | 7/3.0 | 1.4 | 7 | 4.8 | 1.2 | 31.4 |
3 X 50 | 1 X 50 | 1 X 16 | 7 | 8.3 | 1.4 | 7/3.0 | 1.4 | 7 | 4.8 | 1.2 | 34 |
3 X 70 | 1 X 50 | 1 X 16 | 19 | 9.8 | 1.4 | 7/3.0 | 1.4 | 7 | 4.8 | 1.2 | 37 |
3 X 95 | 1 X 50 | 1 X 16 | 19 | 11.6 | 1.6 | 7/3.0 | 1.4 | 7 | 4.8 | 1.2 | 41.4 |
3 X 120 | 1 X 50 | 1 X 16 | 19 | 13 | 1.6 | 7/3.0 | 1.4 | 7 | 4.8 | 1.2 | 44.2 |
3 X 16 | 1 X 50 | 2 X 16 | 7 | 4.8 | 1.2 | 7/3.0 | 1.4 | 7 | 4.8 | 1.2 | 26.2 |
3 X 25 | 1 X 50 | 2 X 16 | 7 | 6 | 1.2 | 7/3.0 | 1.4 | 7 | 4.8 | 1.2 | 28.6 |
3 X 35 | 1 X 50 | 2 X 16 | 7 | 7 | 1.4 | 7/3.0 | 1.4 | 7 | 4.8 | 1.2 | 31.4 |
3 X 50 | 1 X 50 | 2 X 16 | 7 | 8.3 | 1.4 | 7/3.0 | 1.4 | 7 | 4.8 | 1.2 | 34 |
3 X 70 | 1 X 50 | 2 X 16 | 19 | 9.8 | 1.4 | 7/3.0 | 1.4 | 7 | 4.8 | 1.2 | 37 |
3 X 95 | 1 X 50 | 2 X 16 | 19 | 11.6 | 1.6 | 7/3.0 | 1.4 | 7 | 4.8 | 1.2 | 41.4 |
3 X 120 | 1 X 50 | 2 X 16 | 19 | 13 | 1.6 | 7/3.0 | 1.4 | 7 | 4.8 | 1.2 | 44.2 |
FAQ
1. How many years has Henan Jiapu Cable Group been in production?
Founded in October 1998 by Mr. Gu, our facility has three separate manufacturing workshops within its 100, 000-sq. -ft. Building. In 2012, we operates in a new 666, 000 sq. Foot state-of-the-art facility in Xiaodian Industry Park., Xinxiang, Henan, China
2. What kinds of products does Jiapu Cable manufacture?
1)Bare Conductor, such as AAC, AAAC, ACSR, ACAR, AACSR, ACSR/AW and so on;
2)Aerial Bundled Cable (1kV-35kV ), such as Duplex, Triplex, Quadruplex Drop Wires and so on;
3)PVC Insulated (Flexible ) Wire;
4) PVC Insulated and Sheathed (Armoured) Power Cable;
5)Low, Medium, High Voltage (1kV-220kV) XLPE Insulated (Armoured) Power Cable;
6)Welding Cable, Control Cable, Concentric Cable, Rubber Sheathed Cable and so on;
3. What kind of certifications do you have?
SABS, CE, ISO9001-2000, SGS
4. Which markets do you involve mainly in?
Our products have been exported mainly to Africa, Middle East, South-east Asia, South America, Central America, North America, Europe, Australia, etc.
5. Which standards do you comply with when you produce the electrical wires and cables?
We are able to produce electrical wires and cables based on GB, JB, IEC, BS, DIN, ASTM, JIS, NF, AS/NZS, CSA, etc. Meanwhile, we can design and manufacture the cables according to the samples and technical specification the customer supply.
6. What is the min. Order quantity?
It depends on the type and size of electrical wires and cables. For some small electrical wires, 100 meters can be accepted. But for the power cables with medium or high voltage, that should comply with the property of installed equipments. Anyhow, we will try our best to solve the problem and meet with the requirement If you have special request.
7. What is the production capacity per week or per month?
For the bare conductor, we can finish 3000 tons within one month. For power cables, that depends on the type and size. The total output value per month is approx. USD3, 000, 000.00 for insulated aluminum cables and that is approx. USD8, 000, 000.00 for insulated copper cables.
8. Do you supply the customers with installation service in foreign country?
We don’t have professional installation teams in foreign country. But if that is necessary, we will recommend our partners to cooperate with you.