Conductor Quadruplex 600V Secondary Type Urd Cable Aluminum Conductor
Prodotto in dettaglio
Informazioni di Base
Informazioni Aggiuntive.
Descrizione del prodotto
Directly buried or installed in ducts for 600 volt secondary distribution.
Construction
Concentric stranded or compressed 1350-H19 aluminum conductors, crosslinked polyethylene insulation. Insulated conductors surface printed, neutral triple yel low striped. Three phase and one neutral conductor cabled together (LH lay) or parallel if so specified. Black neutrals may be specified is desired.
Standards
Secondary URD quadruplex conductor 600V cable meets or exceeds the following ASTM specifications.
- B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
- B-231 Aluminum 1350 conductors, Concentric-Lay-Stranded.
- B-786 ""19 Wire combination unilay-stranded Aluminum Conductors for subsequent insulation"".
- B-901 ""Compressed round stranded Aluminum Conductors using single input wire construction"".
- Secondary UD quadruplex conductor 600V cable meets or exceeds all applicable requirements of ICEA S-105-692.
- ""USE-2"" per UL 854 available upon request
.Options
- Cable in Duct (CIC)
- Abrasion Resistant
Ampacity
To determine correct ampacity by conductor size, please consult the National Electric Code, latest edition.
The above data is approximate and subjected to manufacturing tolerance.
SERVICING
Purpose:
To establish and maintain a procedure for performing and verifying that our service meets specified requirements and that a suitable method of feedback exists from the customer back to the appropriate individual or department within YIFANG.
Scope:
YIFANG does not currently have any contracts that obligate the company to provide installation or service above and beyond normal product service and delivery. Service activity not specified by contract (such as the treatment of a customer complaint) shall be determined and performed free of charge on a case by case basis. Service concerns will be recorded and will provide a feed-back system as required by the customer.
- Next: Quadruplex Service Drop 600V Aluminum Conductors – ACSR Neutral-Messenger
- Previous: 25kv 35kv Primary Ud Cable Trxlp Insulation
Contact us
Simile o correlato
-
CU/XLPE/CTS/PVC 6.35/11kV scelgono l'IEC di alluminio 60502-2 del cavo elettrico di memoria
-
Al/XLPE/CTS/PVC 19/33kV 36kV scelgono l'IEC di alluminio 60502-2 del cavo elettrico di memoria
-
il collegare corazzato del cavo elettrico del conduttore di alluminio 0.6/1kv digita il prezzo
-
Yjlv22 cavo elettrico corazzato isolato e PVC inguainato di XLPE di potere