Cavo elettrico corazzato isolato XLPE medio del filo di acciaio di tensione
Prodotto in dettaglio
Informazioni di Base
Informazioni Aggiuntive.
Descrizione del prodotto
Payment & Shipping Terms:
Packaging Details: Wooden and steel drum
Payment Terms: L/C, T/T
Supply Ability: 100 Kilogram per Month
1. The products are mainly complying with iec 60502 standard, also can be produced according to OEM requirements and other standards, such as bs standard, DIN standard, ASTM standard, etc.
Voltage grade is up to 35kv, cross-section area can be up to 400 sqmm (copper or aluminiun conductor). Conductor long-time operating temperature is 90 degrees. In short circuit, conductor highest temperature should be not more than 250 degrees.
2. Brief Construction:
Single core or multi-core
Copper or aluminium conductor
XLPE insulation
Copper tape or copper wire screen
Galvanized steel tape armored
PVC or PE sheath
3. Laying conditions: For laying under ground with large different altitude, be able to bear external machanical force and moderate pulling force
4. We can design and manufacture special XLPE cable according to other standards required by customers.
2. Application and Main type
Type | Description | Main Apllication | |
Copper Conductor | Aluminum Conductor | ||
YJV Cu/XLPE/PVC |
YJLV Al/XLPE/PVC |
Copper or aluminum conductor XLPE insulated, Copper tape screen PVC shealthed power cable |
For laying indoor, tunnel, underground and cannel. Unable to bear external mechanical pulling force and pressure during laid. |
YJV Cu/XLPE/L(H)DPE |
YJLV Al/XLPE/L(H)DPE |
Copper or aluminum conductor XLPE insulated, Copper tape screen PE/LDPE/HDPE shealthed power cable |
|
YJE Cu/XLPE/LSOH |
YJLE Al/XLPE/LSOH |
Copper or aluminum conductor XLPE insulated, Copper tape screen LSOH shealthed power cable |
|
YJSV Cu/XLPE/CWS/PVC N2XS(SE)Y |
YJLSV Al/XLPE/CWS/PVC N2XS(SE)Y |
Copper or aluminum conductor XLPE insulated, Copper wire+Coper tape screen PVC shealthed power cable |
For laying indoor, tunnel, underground and cannel. Unable to bear external mechanical pulling force and pressure during laid, fault current requires large. CWS(Copper wire screen) type:A: Fixed section B: Full/one third/one sixth/one eighth/one sixteenth neutral |
YJSY Cu/XLPE/CWS/L(M.H)DPE N2XS(SE)2Y |
YJLSY Al/XLPE/CWS/L(M.H)DPE N2XS(SE)2Y |
Copper or aluminum conductor XLPE insulated, Copper wire+Coper tape screen PE/LDPE/HDPE shealthed power cable |
|
YJE Cu/XLPE/CWS/LSOH |
YJLE Al/XLPE/CWS/LSOH |
Copper or aluminum conductor XLPE Copper wire+Coper tape screen LSOH shealthed power cable |
|
YJV22 Cu/XLPE/STA/PVC |
YJLV22 Al/XLPE/STA/PVC |
Copper or aluminum conductor XLPE insulated, Copper tape screen, steel tape armoured, PVC sheathed power cable |
For laying indoor, tunnel, underground and cannel. Able to bear external mechanical forces, but unable to bear large pulling force. |
YJV23 Cu/XLPE/STA/L(M.H)PE |
YJLV23 Al/XLPE/STA/L(M.H)PE |
Copper or aluminum conductor XLPE insulated, Copper tape screen, steel tape armoured, PE/LDPE/HDPE sheathed power cable |
|
WD-YJY23 Cu/XLPE/STA/LSOH |
WD-YJLY23 Al/XLPE/STA/LSOH |
Copper or aluminum conductor XLPE insulated, Copper tape screen, steel tape armoured, PVC sheathed power cable |
|
YJSV22 Cu/XLPE/CWS/STA/PVC N2XSEBY |
YJLSV22 Al/XLPE/CWS/STA/PVC N2XSEBY |
Copper or aluminum conductor XLPE insulated, Copper wire+Coper tape screen,steel tape armoured, PVC shealthed power cable |
For laying indoor, tunnel, underground and cannel. Able to bear external mechanical forces, but unable to bear large pulling force. fault current requires large. CWS(Copper wire screen) type:A: Fixed section |
3. Scope of voltge grade and core number and cross-section
a) National standard
Rated voltage(kv) | 3.6/6 | 6/6 | 6/10 | 8.7/10 | 8.7/15 | 12/15 | 12/20 | 18/20 | 18/30 | 21/35 | 26/35 | |
Core Number | 1 core, 3 core | |||||||||||
Cross-section mm2 |
1C | 25~800 | 35~800 | |||||||||
3C | 25~400 | 35~400 |
b) IEC/BS/DIN standard
Rated voltage(kv) | 3.6/6 | 6/6 | 6/10 | 8.7/10 | 8.7/15 | 12/15 | 12/20 | 18/20 | 18/30 | 21/35 | 26/35 | |
Core Number | 1 core, 3 core | |||||||||||
Cross-section mm2 |
1C | 25~800 | 35~800 | |||||||||
3C | 25~400 | 35~400 |
c) ASTM standard
Rated voltage(kv) | 5001-8000 | 8001-15000 | 15001-25000 | 25001-28000 | 28001-35000 | 35001-46000 | |
1 core, 3 core | |||||||
Cross-section mm2 |
1C |
6AWG~1600kcmil | 2AWG~1600kcmil | 1AWG~1600kcmil | 2AWG~1600kcmil | 1/0AWG~1600kcmil | |
3C |
1AWG~1600kcmil | 2AWG~1600kcmil | 4/0AWG~1600kcmil |
4. D.C Resistance of finished cable at 20oC per km is not more than following:
Nominal Cross-section mm2 |
25 | 35 | 50 | 70 | 95 | 120 | 150 | 185 | 240 | 300 | |
20oC DC Resistance Ω/km |
Cu | 0.727 | 0.524 | 0.387 | 0.268 | 0.193 | 0.153 | 0.124 | 0.0991 | 0.0754 | 0.0601 |
Al | 1.2 | 0.868 | 0.641 | 0.443 | 0.320 | 0.253 | 0.206 | 0.164 | 0.125 | 0.100 | |
Nominal Cross-section mm2 |
400 | 500 | 630 | 800 | 1000 | 1200 | 1400 | 1600 | 1800 | 2000 | |
20oC DC Resistance Ω/km |
Cu | 0.0470 | 0.0366 | 0.0283 | 0.0221 | 0.0176 | 0.0151 | 0.0123 | 0.0108 | 0.0096 | 0.0086 |
Al | 0.0778 | 0.0605 | 0.0469 | 0.0367 | 0.0291 | 0.0247 | 0.0202 | 0.0177 | 0.0157 | ||
Nominal Cross-section AWG |
6 | 5 | 4 | 3 | 2 | 1 | 1/0 | 2/0 | 3/0 | 4/0 | |
20oC DC Resistance Ω/km |
Cu | 1.3219 | 1.0453 | 0.8298 | 0.6594 | 0.5211 | 0.4149 | 0.3281 | 0.2605 | 0.2065 | 0.1640 |
Al | 2.1699 | 1.7167 | 1.3631 | 1.0802 | 0.8551 | 0.6783 | 0.5401 | 0.4276 | 0.3376 | 0.2688 | |
Nominal Cross-section MCM |
250 | 300 | 350 | 400 | 450 | 500 | 550 | 600 | 650 | 700 | |
20oC DC Resistance Ω/km |
Cu | 0.1386 | 0.1158 | 0.0991 | 0.0865 | 0.0772 | 0.0695 | 0.0630 | 0.0579 | 0.0534 | 0.0495 |
Al | 0.2273 | 0.1897 | 0.1623 | 0.1421 | 0.1263 | 0.1138 | 0.1032 | 0.0948 | 0.0874 | 0.0813 | |
Nominal Cross-section MCM |
750 | 800 | 900 | 1000 | 1100 | 1200 | 1300 | 1400 | 1500 | 1600 | |
20oC DC Resistance Ω/km |
Cu | 0.0463 | 0.0434 | 0.0386 | 0.0347 | 0.0316 | 0.0289 | 0.0237 | 0.0248 | 0.0231 | 0.0217 |
Al | 0.0759 | 0.0711 | 0.0630 | 0.0569 | 0.0518 | 0.0473 | 0.0437 | 0.0405 | 0.0379 | 0.0357 |
- Next: PVC Insulated Flexible Alarm Cable
- Previous: PE Insulated Aerial Bunched Cable
Contact us
Simile o correlato
-
Cavo Al/XLPE/PVC IRAM 2178 3X25/16mm2 standard 0.6/1kV di LV
-
Cavo elettrico corazzato sotterraneo di CEE 0.6/1kV di CU/XLPE/SWA/PVC 4Cx185mm2+1Cx95mm2
-
IEC corazzato 60502-1 del cavo elettrico di LV del cavo del CU di XLPE/SWA/PVC 3C 400mm2
-
cavo elettrico corazzato del CU 0.6/1kV LV di 4Cx2.5sq.mm XLPE/SWA/PVC