Yby, cavo elettrico, 0.6/1 chilovolt, Cu/PVC/PVC/Sta/PVC (IEC 60502-1)
Prodotto in dettaglio
Informazioni di Base
Informazioni Aggiuntive.
Descrizione del prodotto
YBY, Power Cable, 0.6/1 Kv, Cu/PVC/PVC/STA/PVC (IEC 60502-1)
Underground cable with PVC insulation and PVC sheath, steel-tape armoured
Structure:
1 | Copper conductor, round stranded (RM), resp. sectorshaped stranded (SM)
2 | Core insulation (PVC)
3 | Inner covering (EPDM or plastic tape)
4 | Sheath (PVC black)
5 | Armouring (galvanized steel Tape)
6 | Outer covering (plastic tape)
7 | Sheath (PVC black, UV-resistant)
Application:
Power distribution cables in power stations, industrial installations and switchgears, as well as in local mains. For fi xed installation underground, in interior premises, cable ducts, in the open air and in water – as permitted by the local building regulations – if high protection against mechanical damage is required.
Rated voltage: 0.6/1 KV
Test voltage: 3.5 kV/50 Hz
Temperature range:
laying temperature : min. -5ºC
operating temperature: -50ºC-+70ºC
conductor temperature : max. +70ºC
short-circult temperature: max. +160ºC/5 s
Bending radius (min.):
15 x ? of cable (single core)
Core identification:
HD 308 S2
Fire properties:
flame retardant: EN 60332-1-2
reduced flame propagation: EN 60332-3-23
Number of cores x nominal cross section | Max. conductor resistance | Current rating in the ground | Current rating in the air | Outer diameter | Total weight |
(mm²) | (Ω/km) | (A) | (A) | (mm) | (kg/km) |
E-XAYY | |||||
2 x 1.5 RE | 12.100 | 31 | 19 | 11.5 | 200 |
3 x 1.5 RE | 12.100 | 26 | 19 | 12 | 225 |
4 x 1.5 RE | 12.100 | 26 | 19 | 13.0 | 250 |
5 x 1.5 RE | 12.1 | 18 | 14 | 14.0 | 285 |
2 x 2.5 RE | 7.41 | 41 | 26 | 12.3 | 240 |
3 x 2.5 RE | 7.41 | 35 | 24 | 12.5 | 270 |
4 x 2.5 RE | 7.410 | 35 | 24 | 13.6 | 305 |
5 x 2.5 RE | 7.41 | 24 | 19 | 15.5 | 370 |
2 x 4 RE | 4.61 | 52 | 36 | 15.0 | 420 |
3 x 4 RE | 4.61 | 44 | 33 | 15.5 | 460 |
4 x 4 RE | 4.61 | 44 | 33 | 16.0 | 530 |
5 x 4 RE | 4.61 | 31 | 25 | 18.0 | 625 |
2 x 6 RE | 3.08 | 66 | 46 | 16.0 | 475 |
3 x 6 RE | 3.08 | 56 | 41 | 17.0 | 555 |
4 x 6 RE | 3.08 | 56 | 41 | 18.0 | 655 |
5 x 6 RE | 3.08 | 40 | 31 | 19.5 | 760 |
2 x 10 RE | 1.83 | 87 | 64 | 18.0 | 630 |
3 x 10 RE | 1.83 | 75 | 57 | 19.0 | 745 |
4 x 10 RE | 1.83 | 75 | 57 | 20.2 | 940 |
5 x 10 RE | 1.83 | 53 | 42 | 21.6 | 1,090 |
4 x 10 RM | 1.83 | 75 | 57 | 20.5 | 975 |
5 x 10 RM | 1.83 | 53 | 42 | 22.0 | 1,110 |
2 x 16 RE | 1.15 | 112 | 86 | 19.0 | 845 |
3 x 16 RE | 1.15 | 98 | 75 | 21.3 | 985 |
4 x 16 RE | 1.15 | 98 | 75 | 23.2 | 1,240 |
5 x 16 RE | 1.15 | 69 | 57 | 25.5 | 1,520 |
3 x 16 RM | 1.15 | 98 | 75 | 22.0 | 1,030 |
4 x 16 RM | 1.15 | 98 | 75 | 24.0 | 1,290 |
5 x 16 RM | 1.15 | 69 | 57 | 26.0 | 1,500 |
4 x 25 RM | 0.727 | 128 | 102 | 27.5 | 1,830 |
4 x 35 SM | 0.524 | 154 | 125 | 28.7 | 2,040 |
3 x 50 + 25 SM/RM | 0.387/0.727 | 182 | 152 | 32.0 | 2,460 |
3 x 70 + 35 SM/RM | 0.268/0.524 | 225 | 193 | 36.0 | 3,350 |
3 x 95 + 50 SM/RM | 0.193/0.387 | 272 | 239 | 39.0 | 4,200 |
3 x 120 + 70 SM/RM | 0.153/0.268 | 308 | 276 | 44.0 | 5,250 |
3 x 150 + 70 SM/RM | 0.124/0.268 | 348 | 316 | 49.0 | 6,290 |
3 x 185 + 95 SM/RM | 0.099/0.193 | 394 | 363 | 56.0 | 7,720 |
3 x 240 + 120 SM/RM | 0.075/0.153 | 459 | 432 | 59.0 | 9,830 |
- Next: ACSR, Type Asx, All-Greased Aluminium Conductors Steel Reinforced (GOST 839-80)
- Previous: AAAC Conductor, Type Ah, All Aluminium Alloy Conductor (GOST 839-80)
Contact us
Simile o correlato
-
Cavo di controllo flessibile libero dell'alogeno basso 1X0.75mm2 LSZH del fumo 300/500V
-
Basso cavo elettrico di rame isolato PVC di tensione dell'armatura non magnetica del nastro 1X50mm2
-
Cavo di controllo flessibile libero dell'alogeno basso 2X0.75mm2 LSZH del fumo 300/500V
-
Cavo di controllo flessibile libero dell'alogeno basso 2X1.5mm2 LSZH del fumo 300/500V