Cavo medio di tensione di N2xsh, isolamento di XLPE, cavo di rame del fodero del PVC
Prodotto in dettaglio
Informazioni di Base
Informazioni Aggiuntive.
Descrizione del prodotto
N2XSH Medium Voltage cable, Xlpe Insulation, PVC sheath Copper Cable
Application:
They are used in cable ducts, outdoor and indoor installations, under ground where the short circuit levels are high and industrial areas fed by electrical also these cables use where there is risk of mechanical damage.
DIN VDE 0276-620
HD 620 S1: 1996
IEC 60502-2
DIN EN 60228 class 2 (construction)
Construction:
Conductor:Copper or Aluminium
Insulation:XLPE/PVC
Inner sheath:PVC or PE
Outer Sheath:PVC or PE
NO. of cable cross: 1 core(Single core),2cores(Double cores),3cores, 4cores(4 equal-section-area cores OR 3 equal-section-area+1 small section area neutral core),5cores(5 3 equal-section-area cores+2 small area neutral cores OR 4 equal-section-area +1 small area neutral cores).We provide armored type and non-armored type for the cables stated above.
Also can do according to the customer’s request.
Characters:
a.Max Long-time operating temperature of PVC insulated cable is 70°C
b.Installing temperature of cable should not be less than 0°C
c.Max short-circuit temperature is not exceed 160°C,Not more than5 Sec.
d.Permitting bending radius cable: Not less than 10 D times (D:external diameter of cable)
Description & Application:
TECHNICAL FEATURES |
||||||||
Rated Cross |
Overall Diameter |
Current Carrying |
Operating |
Operating |
Conductor DC |
Net |
Delivery |
|
mm2 |
mm |
Air (A) |
Ground (A) |
mH/Km |
µF/Km |
Ohm/Km |
Kg/Km |
Mt |
1×35/16 |
33.00 |
169 |
165 |
0,69 |
0,12 |
0,524 |
1285 |
1000 |
1×50/16 |
35.00 |
249 |
232 |
0,66 |
0,13 |
0,387 |
1460 |
1000 |
1×70/16 |
36.00 |
308 |
284 |
0,63 |
0,14 |
0,268 |
1710 |
1000 |
1×95/16 |
38.00 |
375 |
339 |
0,60 |
0,15 |
0,193 |
2025 |
1000 |
1×120/16 |
40.00 |
430 |
385 |
0,59 |
0,17 |
0,153 |
2300 |
1000 |
1×150/25 |
41.00 |
485 |
430 |
0,57 |
0,18 |
0,124 |
2705 |
1000 |
1×185/25 |
43.00 |
554 |
484 |
0,55 |
0,19 |
0,0991 |
3100 |
1000 |
1×240/25 |
45.00 |
653 |
559 |
0,53 |
0,21 |
0,0754 |
3700 |
1000 |
1×300/25 |
48.00 |
739 |
627 |
0,51 |
0,23 |
0,0601 |
4360 |
1000 |
1×400/35 |
52.00 |
842 |
701 |
0,49 |
0,25 |
0,0470 |
5400 |
500 |
1×500/35 |
55.00 |
965 |
786 |
0,48 |
0,27 |
0,0366 |
6485 |
500 |
1×630/35 |
60.00 |
1096 |
875 |
0,46 |
0,30 |
0,0283 |
7950 |
500 |
Advantages:
a. Excellent electric and mechanical characteristics
b. Best Resistance chemical corrosion and heat-ageing,environment stress and flame-retardant
c. Simple in structure
d. Convenient to use
e. Light weight,perfect bending properties
- Next: H05V-U, H07V-R Single Core Copper PVC Insulated Wire and Cable