Nyy-J, Power/Control Cable, 0.6/1 Kv, Cu/PVC/PVC (BS EN/IEC 60502-1)
Prodotto in dettaglio
Informazioni di Base
Informazioni Aggiuntive.
Descrizione del prodotto
NYY-J, Power/Control Cable, 0.6/1 KV, CU/PVC/PVC (BS EN/IEC 60502-1)
Application:
Power and control cable for fixed installation. Can be used indoors, outdoors, underground, in concrete and in water.
CONSTRUCTION
Conductor
RE: Class 1 solid copper conductor according to BS EN 60228 (previously BS 6360)
RM: Class 2 stranded copper conductor according to BS EN 60228 (previously BS 6360)
Insulation
PVC (Polyvinyl Chloride)
Filler
PVC (Polyvinyl Chloride)
Sheath
FR-PVC (Flame Retardant – Polyvinyl Chloride)
CHARACTERISTICS
Voltage Rating (Uo/U)
600/1000V
Temperature Rating
Fixed: -15°C to +70°C
Flexed: -5°C to +50°C
Minimum Bending Radius
Fixed: 12 x overall diameter
Core Identification
Up to and including 5 core: colour coded or number coded
7 core and above: number coded
Sheath Colour
Black
NO. OF CORES | NOMINAL CROSS SECTIONAL AREA | CONDUCTOR TYPE | NOMINAL THICKNESS OF INSULATION | NOMINAL THICKNESS OF SHEATH | NOMINAL OVERALL DIAMETER | NOMINAL WEIGHT |
mm² | mm | mm | mm | kg/km | ||
1 | 2.5 | RE | 0.8 | 1.4 | 6.15 | 62 |
1 | 4 | RE | 1 | 1.4 | 7.5 | 85 |
1 | 6 | RE | 1 | 1.4 | 7.5 | 108 |
1 | 10 | RM | 1 | 1.4 | 8.6 | 155 |
1 | 16 | RM | 1 | 1.4 | 9.6 | 218 |
1 | 25 | RM | 1.2 | 1.4 | 11.1 | 318 |
1 | 35 | RM | 1.2 | 1.4 | 12.1 | 414 |
1 | 50 | RM | 1.4 | 1.4 | 13.7 | 552 |
1 | 70 | RM | 1.4 | 1.4 | 15.5 | 750 |
1 | 95 | RM | 1.6 | 1.5 | 17.6 | 1020 |
1 | 120 | RM | 1.6 | 1.6 | 19.3 | 1259 |
1 | 150 | RM | 1.8 | 1.6 | 21 | 1546 |
1 | 185 | RM | 2 | 1.7 | 23.2 | 1913 |
1 | 240 | RM | 2.2 | 1.8 | 26.2 | 2471 |
1 | 300 | RM | 2.4 | 2 | 29.2 | 3097 |
2 | 1.5 | RE | 0.8 | 1.8 | 10 | 147 |
2 | 2.5 | RE | 0.8 | 1.8 | 10.7 | 179 |
2 | 4 | RM | 1 | 1.8 | 13 | 268 |
2 | 6 | RM | 1 | 1.8 | 14.2 | 337 |
2 | 10 | RM | 1 | 1.8 | 16.2 | 472 |
2 | 16 | RM | 1 | 1.8 | 18.2 | 644 |
3 | 1.5 | RE | 0.8 | 1.8 | 10.4 | 166 |
3 | 2.5 | RE | 0.8 | 1.8 | 11.3 | 212 |
3 | 4 | RE | 1 | 1.8 | 13.1 | 299 |
3 | 4 | RM | 1 | 1.8 | 13.8 | 318 |
3 | 6 | RE | 1 | 1.8 | 14.2 | 380 |
3 | 6 | RM | 1 | 1.8 | 15 | 402 |
3 | 10 | RM | 1 | 1.8 | 17.1 | 570 |
3 | 16 | RM | 1 | 1.8 | 19.2 | 789 |
3 | 25 | RM | 1.2 | 1.8 | 22.1 | 1141 |
3 | 35 | RM | 1.2 | 1.8 | 24.1 | 1462 |
3 | 50 | RM | 1.4 | 1.8 | 27.6 | 1964 |
3 | 70 | RM | 1.6 | 2.1 | 36.3 | 3635 |
3 | 95 | RM | 1.6 | 2.2 | 40 | 4488 |
4 | 1.5 | RE | 0.8 | 1.8 | 11.6 | 198 |
4 | 2.5 | RE | 0.8 | 1.8 | 12.1 | 252 |
4 | 4 | RE | 1 | 1.8 | 14 | 355 |
4 | 4 | RM | 1 | 1.8 | 15.1 | 391 |
4 | 6 | RE | 1 | 1.8 | 15.4 | 465 |
4 | 6 | RM | 1 | 1.8 | 16.5 | 501 |
4 | 10 | RM | 1 | 1.8 | 18.6 | 702 |
4 | 16 | RM | 1 | 1.8 | 21.1 | 992 |
4 | 25 | RM | 1.2 | 1.8 | 24.2 | 1431 |
4 | 35 | RM | 1.2 | 1.8 | 26.6 | 1861 |
4 | 50 | RM | 1.4 | 1.9 | 30.9 | 2535 |
4 | 70 | RM | 1.4 | 2.1 | 35.1 | 3441 |
4 | 95 | RM | 1.6 | 2.2 | 40.4 | 4691 |
4 | 120 | RM | 1.6 | 2.4 | 44.2 | 5757 |
4 | 150 | RM | 1.8 | 2.5 | 48.5 | 7095 |
4 | 185 | RM | 2 | 2.7 | 53.9 | 8810 |
4 | 240 | RM | 2.2 | 2.9 | 61.1 | 11400 |
5 | 1.5 | RE | 0.8 | 1.8 | 12 | 232 |
5 | 2.5 | RE | 0.8 | 1.8 | 13.1 | 302 |
5 | 4 | RE | 1 | 1.8 | 15.2 | 428 |
5 | 4 | RM | 1 | 1.8 | 16.6 | 477 |
5 | 6 | RE | 1 | 1.8 | 16.5 | 551 |
5 | 6 | RM | 1 | 1.8 | 18.2 | 618 |
5 | 10 | RM | 1 | 1.8 | 20.3 | 853 |
5 | 16 | RM | 1 | 1.8 | 23.1 | 1212 |
5 | 25 | RM | 1.2 | 1.8 | 26.6 | 1759 |
7 | 1.5 | RE | 0.8 | 1.8 | 12.9 | 280 |
7 | 2.5 | RE | 0.8 | 1.8 | 14.1 | 368 |
12 | 1.5 | RE | 0.8 | 1.8 | 16.6 | 475 |
12 | 2.5 | RE | 0.8 | 1.8 | 18.2 | 628 |
14 | 1.5 | RE | 0.8 | 1.8 | 17.1 | 515 |
19 | 1.5 | RE | 0.8 | 1.8 | 18.9 | 648 |
19 | 2.5 | RE | 0.8 | 1.8 | 20.3 | 843 |
27 | 1.5 | RE | 0.8 | 1.8 | 22.6 | 895 |
- Next: Acss/Aw, Aluminium Conductors Steel Supported (ASTM B 856)