Cavo di alimentazione AAC ACSR ACar Acss/Tw Gsw ABC Del Conduttore di trasmissione


                                 Cavo di alimentazione AAC ACSR ACar Acss/Tw Gsw ABC Del Conduttore di trasmissione

Informazioni di Base

Model No..
ACSR

Tipo
Nudo

Tipo di conduttore
Stranded

Applicazione
Alto

Materiale di isolamento
Nudo

Forma Materiale
Filo tondo

Certificazione
ISO9001 ,
CE ,
UL ,
CCC ,
RoHS

Informazioni Aggiuntive.

Marchio
Huatong

Imballaggio
Wooden Drum

Standard
6/1+26/7+84/19

Origine
China

Codice SA
761490000

Capacità di Produzione
2000 Ton Per Month

Descrizione del prodotto

Overhead conductor AAC AAAC ACSR ACAR ACS ACSS/TW ABC Cable
(1)Production capacity:5000 ton/month
(2)MOQ:1km
(3)Delivery:5~15 officail days.
(4)Standards:IEC,ASTM,DIN,BS; or according to customers’ requirements.
(5)Delivery length:as per customers’ request.

1,Bare Conductor Types
(1) all aluminum conductor (AAC)
(2) all aluminum alloy conductor(AAAC)
(3) aluminum conductor steel reinforced (ACSR)
(4) anti-corrosion type ACSR
(5) aluminum conductor aluminum clad steel reinforced(ACSR/AW)
(6) rear earth aluminum conductor steel reinforced(ACSR/RE)
(7) aluminum conductor aluminum alloy reinforced(ACAR)
(8)aluminium Conductor Steel Supported (ACSS)

2. ACSR (Aluminum conductor steel reinforced)
  (1),Brief Description
ACSR conductor consists of a solid or stranded steel core surrounded by strands of aluminium (E.C.GRADE).
  (2),Application
Widely used in power transmission lines with various voltage levels, because they have such good characteristics as simple structure, convenient installation and maintenance, low cost large transmission capacity. And they are also suitable for laying across rivers valleys and the places where special geographical features exist.

3.ACAR Conductor,Aluminum Conductor Aluminium Alloy Reinforced.
(ACAR) is an excellent conductor choice where current carrying capacity,higher strength and a lower conductor weight are critical to the line design.

4.AAAC, All Aluminum Alloy Conductor
(1). Standard: BS EN 50183, ASTM B399, DIN 48201
(2). Specification: AAAC are composed by bare concentric-lay-stranded aluminium alloy wires.
(3). Application: Used as bare overhead conductor for primary and secondary distribution. Designed utilizing a high-strength aluminum alloy to achieve a high strength-to-weight ratio; affords better sag characteristics. Aluminum alloy gives AAAC higher resistance to corrosion than ACSR.

5.ACSS,( Overhead Aluminium Conductor Steel Supported).
  (1), Construction
       a non-homogenous conductor, is a concentric-lay stranded conductor made from round aluminum 1350-O wires and round, coated steel core wire(s). Steel wires are coated with Class A coating of zinc – 5% aluminum mischmetal alloy. Other Classes of coatings are also available for additional protection from corrosion. Standard, High, Extra and Ultra High Strength steel are also available.
  (2),Features
ACSS conductors are preferred over ACSR conductors for specific transmission line applications:
With zinc – 5% aluminum mischmetal alloy coating on steel wires, ACSS conductors can be operated up to 250 °C.
ACSS conductors carry more current than ACSR conductors due to:Minimum average conductivity of 63% IACS for 1350-O aluminum wires vs. an average conductivity of 61.2% for 1350-H19 aluminum wires in ACSR.
ACSS conductors can be operated up to 250 °C vs. the maximum operating temperature for an ACSR conductor does not exceed 100 °C.
ACSS conductors are prone to resist the effects of aeolian vibration due to very little or no mechanical load on the annealed aluminum wires.
Long term creep is not a factor when designing with ACSS conductors.

6. GSW(Galvanized Steel Wire) ; Guy Wire,Stay Wire 
    (1) Technical Data
         Hot-Dipped Galvanized steel wire
         Diameter:1.24~5.50mm
         Zinc Coating:150-400g/m2 ASTM class A. class B.
        Tensile Strength:900-1720 mpa.
         Intensity Level:General,High,Very High.
         Min.No. of 360° twists:10~16.
         Construction:1×3,1×7,1×19.1×37.
    (2) Application
         Used as overhead ground wire or static wire on transmission lines, as pole or structure guy wires, and as messenger cable, fields and pastures division, animal containment.

7. ABC Cable (Aerial Bundled Cable) has characters of power-transmitting and strong mechanical. In comparison with bare wire, aerial bundled cable (ABC cable) boasts many advantages, such as:small span in laying, higher safe reliability, better atmosphere aging resistence property. Aerial bundled cable has the priority to be used in urban and rural power-transmitting construction project.
    Insulation: PVC or XLPE
    ABC Cable Technical characteristics  (Duplex Service Drop

Code
Word
Phase Conductors Bare Natural Nominal Weight Ampacity Standard Package
Size &
Number
of wires
Insulation
Thickness
Nominal Diameter Size &
Number
of Wires
Rated
Strength
kg / km Coils Reels
Bare OD XLPE Aluminum Total
mm mm mm kg A m m
                         
AAC
Pekingese 6-Solid 1.14 4.1 6.4 6-7 255 20.8 72.9 94 78 305 1000
Collie 6-7 1.14 4.6 6.9 6-7 255 23.8 72.9 97 78 305 1000
Cocker 6-7 1.52 4.6 7.7 6-7 255 32.7 72.9 106 78 305 1000
Dachshund 4-Solid 1.14 5.2 7.5 6-7 400 26.8 114.6 141 103 305 500
Spaniel 4-7 1.14 5.9 8.2 6-7 400 29.8 116.1 146 103 305 500
Cairn 4-7 1.52 5.9 8.9 6-7 400 40.2 116.1 156 103 305 500
Doberman 2-7 1.14 7.4 9.7 2-7 612  38.7 184.5 223 136 152 500
Airedale 1-19 1.52 8.4 11.5 1-7 56.5 233.6 290 158 152 500
Basset 1/0-7 1.52 9.3 12.4 1/0-7 903  64.0  294.7 359 182 152 457
Malemure 1/0-19 1.52 9.4 12.5 1/0-7 903  64.0  294.7 359 182 152 457
                         
AAAC
Chihuahua 6-Solid 1.14 4.1 6.4 6-7 499 20.8 72.9 94 78 305 1000
Vizsla 6-7 1.14 4.6 6.9 6-7 499 23.8 72.9 97 78 305 1000
Harrier 4-Solid 1.14 5.2 7.5 4-7 798 26.8 116.1 143 103 305 500
Whippet 4-7 1.14 5.9 8.2 4-7 798 29.8 116.1 146 103 305 500
Schnauzer 2-7 1.14 7.4 9.7 2-7 1,270  38.7 184.5 223 136 152 500
Afghan 1/0-7 1.52 9.3 12.4 1/0-7 2,023  64.0  296.1 360 182 152 457
heeler 1/0-19 1.52 9.4 12.5 1/0-7 2,023  64.0  296.1 360 182 152 457
                         
ACSR
Setter 6-Solid 1.14 4.1 6.4 6/6/01 540 20.8 72.9 94 78 305 1000
Shepherd 6-7 1.14 4.6 6.9 6/6/01 540 23.8 72.9 97 78 305 1000
Retriever 6-7 1.52 4.6 7.7 6/6/01 540 32.7 72.9 106 78 305 1000
Eskimo 4-Solid 1.14 5.2 7.5 4/6/01 844 26.8 114.6 141 103 305 500
Terrier 4-7 1.14 5.9 8.2 4/6/01 844 29.8 116.1 146 103 305 500
Yorkshire 4-7 1.52 5.9 8.9 4/6/01 844 40.2 116.1 156 103 305 500
Chow 2-7 1.14 7.4 9.7 2/6/01 1,293  38.7 184.5 223 136 152 500
Labrador 1-19 1.52 8.4 11.5 1/6/01 1,610  56.5 233.6 290 158 152 500
Bloodhound 1/0-7 1.52 9.3 12.4 1/0-6/1 1,987  64.0  294.7 359 182 152 457
Bull 1/0-19 1.52 9.4 12.5 1/0-6/1 1,987  64.0  294.7 359 182 152 457

8.Power cable
(1) 0.6/1kv PVC Cable
(2) 0.6/1kv XLPE Cable
(3) 1.9/3.3kv XLPE Cable
(4) 3.6/6kv XLPE Cable
(5) 3.8/6.6kv XLPE Cable
(6) 6/10kv XLPE Cable
(7) 6.35/11kv XLPE Cable
(8) 8.7/15kv XLPE Cable
(9) 12/20kv XLPE Cable
(10) 12.7/22kv XLPE Cable
(11) 18/30kv XLPE Cable
(12) 19/33kv XLPE Cable
(13) 21/35kv XLPE Cable
(14) 26/35kv XLPE Cable

9.Huatong Cable Inc. 
1,More than 30 years experience.
2,100,000m² factory,200 staffs,annual output 100,000 metic tons.
3,Sound Quality Control
   (1) Material inspection;
   (2) manufacturing inspection;
   (3) Finished products inspection;
   (4) Inspection before delivery.
   (5) Third party inspection.
   (6) Inspection of storage at port of departure.
4,ISO Certificated.
5,Plenty of material and lobor gurantee the delivery prompt and price competitive.
6,24/7 service.

10.  IEC61089 Standard  AAAC

Code Number            A2 Conductor                      A3 Conductor Max.D.C. Resistance of Conductor at 20°C
Number of Wires Diameter of Wires Diameter of Conductor Approx. Weight Rated Strength Number of Wires Diameter of Wires Diameter of Conductor Approx. Weight Rated Strength
mm² mm  mm kg/km   daN mm  mm kg/km   daN Ω/km
 16 7 1.83 5.49  50.4  5.43    50.8  6.04  50.8  6.04 1.7896
 25 7 2.29 6.87  78.7  8.49 1.1453  79.5  9.44  79.5  9.44 1.1453
 40 7 2.89 8.67 125.9  13.58 0.7158  127.1  15.1  127.1  15.1 0.7158
 63 7 3.63  10.8 198.3 21.39 0.4545 200.2 23.06 200.2 23.06 0.4545
100 19 2.78  13.9 316.3 33.95 0.2877 319.3 37.76 319.3 37.76 0.2877
125 19 3.10  15.5 395.4 42.44 0.2302 399.2 47.20 399.2 47.20 0.2302
160 19 3.51 17.55 506.1 54.32 0.1798 511.0 58.56 511.0 58.56 0.1798
200 19 3.93 19.65 623.7  67.91 0.1439 638.7 73.20 638.7 73.20 0.1439
250 19 4.39 21.95 790.8 84.68 0.1151 798.4 91.50 798.4 91.50 0.1151
315 37 3.53 24.71 998.9 106.95 0.0916 1008.4 115.29 1008.4 115.29 0.0916
400 37 3.98 27.86 1268.4 135.81 0.0721 1280.5 146.4o 1280.5 146.4o 0.0721
450 37 4.22 29.54 1426.9 152.79 0.0641 1440.5 164.70 1440.5 164.70 0.0641
500 37 4.45 31.15 1585.5 169.76 0.0577 1600.6 183.oo 1600.6 183.oo 0.0577
560 61 3.67 33.03 1778.4 190.14 0.0516 1795.3 204.95 1795.3 204.95 0.0516
630 61 3.89 35.01 2000.7 213.90 0.0458 2019.8 230.58 2019.8 230.58 0.0458
710 61 4.13 37.17 2254.8 241.07 0.0407 2276.2 259.86 2276.2 259.86 0.0407
800 61 4.38 39.42 2540.6 271.62 0.0361 2564.8 282.80 2564.8 282.80 0.0361
900 91 3.81 41.91 2861.1 305.58 0.0632 2888.3 329.40 2888.3 329.40 0.0321
1000 91 4.01 44.11 3179.0 339.53 0.0289 3209.3 366.00 3209.3 366.00 0.0289
1120 91 4.25 46.75 3560.5 380.27 0.0258 3594.4 409.92 3594.4 409.92 0 0258
1250 91 4.49 49.39 3973.7 424.41 0 0231  