Type SHD-GC, Mining Cable, Cu/Epr/TPU, 3/C, 25kv (ICEA S-75-381/NEMA WC-58)
Applications
These heavy duty cables are designed for applications such as longwall shearers, continuous miners, loaders, drills, conveyors, pumps and mobile equipment where grounding conductors, a ground check conductor and metallic shielding are required.
Standards
ICEA S-75-381/NEMA WC 58
ASTM B 172
ASTM B 33
CAN/CSA-C22.2 No.96
Construction
Conductors: Stranded annealed tinned copper conductor.
Insulation: Ethylene Propylene Rubber (EPR).
Insulation Shield: Tinned copper/textile braid.
Ground Check Conductor: Tinned copper conductor with a yellow polypropylene insulation.
Grounding Conductor: Tinned copper conductor.
Jacket: Reinforced extra-heavy-duty Chlorinated Polyethylene (CPE), black.
Options
Other jacket materials such as CSP/PCP/NBR/PVC/TPU are available upon request.
Two-layer jacket with reinforcing fibre between the two layers can be offered as an option.
Mechanical and Thermal Properties
Minimum Bending Radius: 6×OD
Maximum Conductor Operating Temperature: +90ºC
Constructon | No. of Strands | Grounding Conductor Size | Control Conductor Size | Nominal Insulaton Thickness | Nominal Jacket Thickness | Nominal Overall Diameter | Nominal Weight | Ampacity |
No. of cores×AWG/kcmil | AWG/kcmil | AWG/kcmil | inch | inch | inch | lbs/kf | A | |
3×1 | 259 | 5 | 8 | 0.26 | 0.265 | 2.95 | 4410 | 191 |
3×1/0 | 266 | 4 | 8 | 0.26 | 0.265 | 3.05 | 4866 | 218 |
3×2/0 | 323 | 3 | 8 | 0.26 | 0.280 | 3.2 | 5560 | 249 |
3×3/0 | 418 | 2 | 8 | 0.26 | 0.280 | 3.33 | 6192 | 286 |
3×4/0 | 532 | 1 | 8 | 0.26 | 0.295 | 3.5 | 7110 | 327 |