AAAC Aluminium Alloy Conductor ,Bare Conductor,Aaac Cable,Aaac Wire
1. STANDARDS
AAAC-6201 bare conductor meets or exceeds the following ASTM standards:
B-398 Aluminum-Alloy 6201-T81 Wire for Electrical Purposes.
B-399 Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors.

2. CONSTRUCTION
Aluminum alloy 6201 wires, concentrically stranded.

AAAC (All Aluminum Alloy Conductor)have been widely used in power transmission lines with various voltage levels, and also used in power lines across great rivers, heavy ice area, and other places special geographical characteristics. The conductor have excellent advantages of high strength, large current carrying capacity and good catenary property as well as wear-resistance, anti-crush and corrosion-proof with simple structure, convenient installation and maintenance, low cost for the line, large transmission capacity.referred to have higher strength but lower conductivity than pure aluminum.being lighter, alloy conductors can sometimes be used to advantage in place of the more conventional ACSR;having lower breaking loads than the latter,their use becomes particularly favourable when ice and win loadings are low.

Standard
We can supply this conductor according to different recognized standards,such as BS EN50182,IEC61089,ASTM B399,DIN 48 201, customer special specification also can be satisfied.

Advantage

Corrosion Resistance:AAAC exhibits excellent corrosion resistance specially in sea coast areas and in polluted industrial areas due to absence of steel core.

Lower Power losses:Since AAAC is homogeneous (with all strands of Aluminium Alloy) with no steel component the resistance of AAAC is lower as compared to ACSR.

Higher Ampacity:AAAC can carry atleast 15-20% extra current as compared to ACSR of equal size

Longer Life:Experience in foreign countries shows that All Aluminium Alloy Conductors are in service for over 60 years, which is about double the life of ACSR Conductors.

Surface Hardness:The surface hardness of AAAC is 80 BHN as compared to 35 BHN of ACSR. This reduces the damage to surface during handling and therefore leading to lesser corona losses and ratio interference at EHV.

Therma Stability:AAAC are stable upto 90oC against ACSR conductors which are st-able upto 75oC.

Higher Strength To Weight Ratio:Since AAAC has higher strength to weight ratio,span can be increased from 2 to 15% resulting in overall reduction of cost in towers sup-ports and other accessories in transmission line system.

Detailed Product Description:Aluminum-ALLOY Conductor/aaac Cable/aaac conductor

Code
word
Size
(kcmil)
Strand-ing Diameter
(ins.)
Weight
per
1000 ft.
(Lbs)
Rated
strength
(Lbs)
Resistance
Ω/1000 ft.
Allowable
ampacity+
 (Amps)
ACSR with
equiv.diam.
Approx
EC cond.
with
equivalent
resistance
Indivi-
dual
wire
Complete conductor DC at
20ºC
AC at
75ºC
Size Stranding
(AL/STL)
Akron 30.58 7 0.0661 0.198 28.5 1110 .659 .785 107 6 6/1 6
Alton 48.69 7 0.0834 0.250 45.4 1760 .414 .493 143 4 6/1 4
Ames 77.47 7 0.1052 0.316 72.2 2800 .260 .310 191 2 6/1 2
Azusa 123.3 7 0.1327 0.398 115.0 4460 .163 .195 256 1/0 6/1 1/0
Anaheim 155.4 7 0.1490 0.447 144.9 5390 .130 .154 296 2/0 6/1 2/0
Amherst 195.7 7 0.1672 0.502 182.5 6790 .103 .123 342 3/0 6/1 3/0
Alliance 246.9 7 0.1878 0.563 230.2 8560 .0816 .0973 395 4/0 6/1 4/0
Butte 312.8 19 0.1283 0.642 291.7 11000 .0644 .0769 460 266.8 26/7 266.8
Canton 394.5 19 0.1441 0.720 367.9 13300 .0511 .0610 532 336.4 26/7 336.4
Cairo 465.4 19 0.1565 0.783 434.0 15600 .0433 .0518 590 397.5 26/7 397.5
Darien 559.5 19 0.1716 0.858 521.7 18800 .0360 .0431 663 477.0 26/7 477.0
Elgin 652.4 19 0.1853 0.927 608.4 21900 .0309 .0371 729 556.5 26/7 556.5
Flint 740.8 37 0.1415 0.990 690.8 24400 .0272 .0327 790 636.0 26/7 636.0
Greeley 927.2 37 0.1583 1.108 864.6 30500 .0217 .0263 908 795.0 26/7 795.0
+Ampacity based on 75ºC conductor temperature, 25ºC ambient temperature, 2 ft/sec. wind in sun, emissivity 0.5, 52.5% conductivity.

 