Hard-Drawn Aluminum Conductors

 Hard-Drawn Aluminum Conductors

Prodotto in dettaglio

Informazioni di Base

Model No.:aac aaac acsr
Applicazione: Alto
Voltaggio: Cavo a bassa tensione e media
Corrente: Cavo DC
Materiale di isolamento: Nudo
Forma Materiale: Filo tondo
Certificazione: ISO , CCC , CE , RoHS , UL

Informazioni Aggiuntive.

Marchio:RNEDA
Imballaggio:Wooden Drum
Standard:IEC DIN ASTM VDE BS
Origine:China
Codice SA:7614100000
Capacità di Produzione:1000km Per Month

Descrizione del prodotto

hard-drawn aluminum conductors

Standards

IEC61089, BS215 part2, ASTM B232, DIN48204, BS EN50182, JIS C3110

Certificate

ISO 9001 and ISO 14001.

Type

AAC, AAAC, ACSR, AACSR&ACAR conductor

AAC, AAAC, ACSR, AACSR & ACAR conductor widely used in power transmission lines with various voltage levels.Since they have such good characteristics as simple structure, convenient installation and maintenance, low cost for the line, large transmission capacity and are also suitable for laying across rivers and valleys where special geographical teatures exist.

Conductor Specification:
(1) all aluminium conductor (AAC)
(2) all aluminimum alloy conductor(AAAC)

(3) aluminum conductor steel reinforced (ACSR)

(4) anti-corrosion type ACSR

(5) aluminimum conductor aluminimum clad steel reinforced(ACSR/AW)
(6)rear earth aluminimum conductor steel reinforced(ACSR/RE)
(7)aluminimum conductor aluminimum alloy reinforced(ACAR)

All Aluminum Conductor(AAC)& Aluminum Conductor Steel Reinforced(ACSR))for ASTM

(AAC, ACCR, AAAC, ACSR) Generally Confirming to IS 398 (Part-I, II, IV), IEC-228
(AAAC) Conductor as per ASTM-B-399-1992
(AAAC) Conductor as per BS-3242-1970
(AAAC) Conductor IS: 398-IV-1994
(ACSR) as per ASTM-B-233-1992
(AAC) as per BS-215-1-1970
(AAC) as per IS-398-1: 1976
(AAC) as per ASTM-B-231-1990
(ACSR) as per IS: 398-II: 1976 & IS: 398-V: 1992
(ACSR) BS-215-II-1970
(AACSR) as per IEC-1089-1191
AAC(All aluminum conductor) are suited for overhead power line.

Conductor Construction:
Aluminum alloy 1350-H-19 wires, concentrically stranded about a steel core. Core wire for ACSR is available with class A, B, or C galvanizing; ""aluminized"" aluminum coated (AZ); Or aluminum-clad (AW). Additional corrosion protection is available through the application of grease to the corrosion or infusion of the complete cable with grease.

We can supply this conductor according to different recognized standards, distribution and transmission lines for distributing power.

Aluminum Conductors Steel Reinforced ASTM B 232
Code name Area Stranding and wire diameter Approx. overall diameter Weight Nominal breaking load Nominal DC resistance at 20 deg.
Nominal Alum. Steel Total Alum. Steel Alum. Steel Total
AWG or MCM mm2 mm2 mm2 mm mm mm kg/km kg/km kg/km kN Ohm/km
TURKEY 6 13.29 2.19 15.48 6/1.68 1/1.68 5.04 37 17 54 5.24 2.1586
SWAN 4 21.16 3.55 24.71 6/2.12 1/2.12 6.36 58 27 85 8.32 1.3557
SWANATE 4 21.16 5.35 26.51 7/1.96 1/2.61 6.53 58 42 100 10.53 1.3557
SPARROW 2 33.61 5.61 39.22 6/2.67 1/2.67 8.01 92 44 136 12.7 0.8535
SPARATE 2 33.61 8.52 42.13 7/2.47 1/3.30 8.24 92 67 159 16.11 0.8535
RAVEN 1/0 53.48 8.9 62.38 6/3.37 1/3.37 10.11 147 69 216 19.32 0.5364
QUAIL 2/0 67.42 11.23 78.65 6/3.78 1/3.78 11.34 185 88 273 23.62 0.4255
PIGEON 3/0 85.03 14.19 99.22 6/4.25 1/4.25 12.75 233 110 343 29.41 0.3373
PENGUIN 4/0 107.23 17.87 125.1 6/4.77 1/4.77 14.31 294 139 433 37.06 0.2675
PARTRIDGE 266.8 135.16 22 157.16 26/2.57 7/2.00 16.28 374 172 546 50.29 0.2143
MERLIN 336.4 170.45 9.48 179.93 18/3.47 1/3.47 17.35 470 74 544 38.23 0.1691
LINNET 336.4 170.45 27.81 198.26 26/2.89 7/2.25 18.31 472 217 689 62.71 0.1699
ORIOLE 336.4 170.45 39.81 210.26 30/2.69 7/2.69 18.83 473 311 784 77.27 0.1704
IBIS 397.5 201.42 32.77 234.19 26/3.14 7/2.44 19.88 558 256 814 72.11 0.1438
LARK 397.5 201.42 46.97 248.39 30/2.92 7/2.92 20.44 560 367 927 88.69 0.1442
PELICAN 477 241.68 13.42 255.10 18/4.14 1/4.14 20.70 666 105 771 52.16 0.1193
FLICKER 477 241.68 31.29 272.97 24/3.58 7/2.39 21.49 670 245 915 76.66 0.1199
HAWK 477 241.68 39.42 281.10 26/3.44 7/2.67 21.79 670 308 978 86.65 0.1199
HEN 477 241.68 56.39 298.07 30/3.20 7/3.20 22.40 671 441 1112 105.34 0.1201
OSPREY 556.5 282.00 15.68 297.68 18/4.47 1/4.47 22.35 777 122 899 60.88 0.1022
PARAKEET 556.5 282.00 36.58 318.58 24/3.87 7/2.58 23.22 781 286 1067 88.22 0.1027
DOVE 556.5 282.00 45.94 327.94 26/3.72 7/2.89 23.55 781 359 1140 101.03 0.1027
EAGLE 556.5 282.00 65.81 347.81 30/3.46 7/3.46 24.21 783 515 1298 122.92 0.103
PEACOCK 605 306.58 39.74 346.32 24/4.03 7/2.69 24.20 849 311 1160 95.88 0.0945
SQUAB 605 306.58 49.94 356.52 26/3.87 7/3.01 24.51 850 390 1240 108.14 0.0945
TEAL 605 306.58 69.87 376.45 30/3.61 19/2.16 25.24 851 548 1399 133.59 0.0947
GROSBEAK 636 322.26 52.45 374.71 26/3.97 7/3.09 25.15 893 409 1302 111.8 0.08989
STARLING 715.5 362.58 59.03 421.61 26/4.21 7/3.28 26.68 1005 461 1466 125.91 0.07989
TERN 795 402.84 27.87 430.71 45/3.38 7/2.25 27.03 1116 217 1333 97.37 0.07191
CONDOR 795 402.84 52.19 455.03 54/3.08 7/3.08 27.72 1116 408 1524 124.45 0.07191
CUCKOO 795 402.84 52.19 455.03 24/4.62 7/3.08 27.74 1116 408 1524 123.94 0.07191
DRAKE 795 402.84 65.61 468.35 26/4.44 7/3.45 28.11 1116 512 1628 139.92 0.07191
MALLARD 795 402.84 91.87 494.71 30/4.14 19/2.48 28.96 1119 719 1838 171.18 0.07208
RAIL 954 483.42 33.42 516.84 45/3.70 7/2.47 29.61 1339 262 1601 115.63 0.05992
CURLEW 1033.5 523.68 67.87 591.55 54/3.52 7/3.52 31.68 1451 530 1981 161.8 0.05531
BLUEJAY 1113 563.93 39.03 602.96 45/4.00 7/2.66 31.98 1563 305 1868 132.63 0.05136
FINCH 1113 563.93 71.55 635.48 54/3.65 19/2.19 32.85 1570 560 2150 174.41 0.05161